Connection Establishment

Parameter #

Description

Units

 

 

 

 

 

of

31

Line seizure delay timer. Specifies the minimum time between

1 ms (0 ms to

 

 

an outgoing or incoming call and the automatic dialing of

15000 ms) outgoing c

 

Country

 

Default

 

 

 

 

United States

5000

 

 

 

 

Australia

 

5000

 

 

 

 

France

 

6500

 

 

 

 

Germany

 

7000

 

 

 

 

Netherlands

7000

 

 

 

 

United Kingdom

3500

 

 

 

 

India

 

5000

 

 

 

 

Korea

 

5000

 

 

 

 

China

 

5000

 

 

 

 

 

 

 

is

32

Pre OFF hook shunt. Defines the time the LIU shunt will be active1ms (0 ms to

 

 

activated just prior to when HP OfficeJet Series 300 goes OFF hook1000 ms)

 

 

 

by all LIUs.

 

 

 

 

 

 

Country

 

Default

 

 

 

 

United States

0

 

 

 

 

Australia

 

325

 

 

 

 

France

 

0

 

 

 

 

Germany

 

0

 

 

 

 

Netherlands

0

 

 

 

 

United Kingdom

0

 

 

 

 

India

 

0

 

 

 

 

Korea

 

0

 

 

 

 

China

 

0

 

 

 

 

 

 

 

 

 

 

33

(Reserved)

 

 

 

 

 

 

 

 

 

test is

34

Modem loop current failure test enable. Controls is a modem

0 = FALSE

 

 

performed after HP OfficeJet Series 300 has dialed a number or

1 = TRUE

 

 

 

answered an incoming call. If TRUE it will continuously test

absence of

 

loop current. If no loop current is detected the fax session

aborted.

 

Country

 

Default

 

 

 

 

United States

0

 

 

 

 

Australia

 

0

 

 

 

 

France

 

0

 

 

 

 

Germany

 

0

 

 

 

 

Netherlands

0

 

 

 

 

United Kingdom

0

 

 

 

 

India

 

0

 

 

 

 

Korea

 

0

 

 

 

 

China

 

0

 

 

 

Problem Resolution5-59