Connection Establishment

Parameter #

Description

Units

31

32

33

34

Line seizure delay timer. Specifies the minimum time between

1 ms (0 ms to

of

an outgoing or incoming call and the automatic dialing of

15000 ms) outgoing ca

Country

Default

 

 

United States

5000

 

 

Australia

5000

 

 

France

6500

 

 

Germany

7000

 

 

Netherlands

7000

 

 

United Kingdom

3500

 

 

India

5000

 

 

Korea

5000

 

 

China

5000

 

 

 

 

 

is

Pre OFF hook shunt. Defines the time the LIU shunt will be active1ms (0 ms to

activated just prior to when HP OfficeJet Series 300 goes OFF hook1000 ms)

 

by all LIUs.

 

 

 

Country

Default

 

 

United States

0

 

 

Australia

325

 

 

France

0

 

 

Germany

0

 

 

Netherlands

0

 

 

United Kingdom

0

 

 

India

0

 

 

Korea

0

 

 

China

0

 

 

 

 

 

 

(Reserved)

 

 

 

 

 

test is

Modem loop current failure test enable. Controls is a modem

0 = FALSE

performed after HP OfficeJet Series 300 has dialed a number or

1 = TRUE

 

answered an incoming call. If TRUE it will continuously test

absence of

loop current. If no loop current is detected the fax session

aborted.

Country

Default

 

 

United States

0

 

 

Australia

0

 

 

France

0

 

 

Germany

0

 

 

Netherlands

0

 

 

United Kingdom

0

 

 

India

0

 

 

Korea

0

 

 

China

0

 

 

 

 

 

 

Problem Resolution5-59

Page 98
Image 98
HP 330, 350 manual Connection Establishment