Parameter #

Description

Units

71

72

73

74

Dial pulse break time. The duration that the dial pulse relay1

ms

opened to

cause a break of loop current during pulse dialing. This

(10 ms to

 

by the

LIU.

 

 

100 ms)

 

 

Country

Default

 

 

 

United States

60

 

 

 

 

Australia

67

 

 

 

 

France

66

 

 

 

 

Germany

60

 

 

 

 

Netherlands

61

 

 

 

 

United Kingdom

67

 

 

 

 

India

62

 

 

 

 

Korea

66

 

 

 

 

China

62

 

 

 

 

 

 

 

to ca

Dial pulse make time. The duration that the dial pulse relay

1 ms

 

a make of loop current during pulse dialing. This parameter(10

ms to

 

LIU.

Country

Default

100 ms)

 

 

United States

40

 

 

 

 

Australia

33

 

 

 

 

France

34

 

 

 

 

Germany

40

 

 

 

 

Netherlands

39

 

 

 

 

United Kingdom

33

 

 

 

 

India

38

 

 

 

 

Korea

34

 

 

 

 

China

38

 

 

 

 

Dial pulse interdigit time. The duration between digits when

1 ms

 

 

measured from the end of the last make to the start of the

(400 ms to

 

of the ne

digit.

 

 

1500 ms)

 

 

Country

Default

 

 

 

United States

800

 

 

 

 

Australia

800

 

 

 

 

France

900

 

 

 

 

Germany

800

 

 

 

 

Netherlands

800

 

 

 

 

United Kingdom

800

 

 

 

 

India

800

 

 

 

 

Korea

800

 

 

 

 

China

800

 

 

 

 

DTMF transmit level high group. The DTMF transmit level for

1 (0 to 150)

 

of

frequencies in the DTMF tone pair.

 

 

 

Country

Default

 

 

 

United States

50

(–0.1 dBm)

 

 

 

Australia

90

(–0.1 dBm)

 

 

 

France

60

(–0.1 dBm)

 

 

 

Germany

70

(–0.1 dBm)

 

 

 

Netherlands

90

(–0.1 dBm)

 

 

 

United Kingdom

90

(–0.1 dBm)

 

 

 

India

70

(–0.1 dBm)

 

 

 

Korea

60

(–0.1 dBm)

 

 

 

China

70

(–0.1 dBm)

 

 

 

 

 

 

 

 

 

Problem Resolution5-71

Page 110
Image 110
HP 330, 350 manual Liu