HP manual Using the HP E1368A/69A/70A Modules, Microwave Switch Commands

Models: E1368A

1 86
Download 86 pages 17.67 Kb
Page 29
Image 29

Chapter 3

Using the HP E1368A/69A/70A Modules

Using This Chapter

This chapter uses typical examples to show how to use the Microwave

Switch modules. This chapter contains the following sections:

Microwave Switch Commands . . . . . . . . . . . . . . . . . . . . . . . Page 29

Reset Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 30

Switching Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31

Scanning Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 39

Recalling and Saving States. . . . . . . . . . . . . . . . . . . . . . . . . . Page 43

Detecting Error Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . Page 43

Synchronizing the Microwave Switch. . . . . . . . . . . . . . . . . . Page 45

Querying the Microwave Switch . . . . . . . . . . . . . . . . . . . . . . Page 46

Microwave Switch Commands

Table 3-1. Microwave Switch Commands in Chapter 3

Command

Command Description

 

 

 

 

INIT[:IMM]

Starts the scan sequence and closes the first channel in

 

the channel list.

OUTP[:STAT] ON

Enables the HP E1300A/E1301A "Trig Out" port to

 

output pulses.

[ROUT:]CLOS <channel_list>

Close the channels in the channel list.

[ROUT:]CLOS? <channel_list>

Query the state of the channels in the channel list.

[ROUT:]OPEN <channel_list>

Open the channels in the channel list.

[ROUT:]SCAN <channel_list>

Closes the channels in the channel list one at a time.

TRIG:SOUR BUSEXTHOLDIMM

Select the trigger source to advance the scan.

*CLS

Clears all switchbox Status Registers.

*ESE

Enables the Event Status Register.

*RST

Sets the hardware and software to a known state.

*SRE

Enables the Status Register.

 

 

 

 

Chapter 3

Using the HP E1368A/69A/70A Modules 29

Page 29
Image 29
HP manual Using the HP E1368A/69A/70A Modules, Microwave Switch Commands