This option specifies the parity mode for each transmitted character. If the number of data bits specified by Word Length is 8, set this option to None.

Selecting Odd will cause an eighth bit to be added with a value of 1 if the previous 7 bits add up to an even number, and 0 if the previous 7 bits add up to an odd number.

Selecting Even will cause an eighth bit to be added with a value of 1 if the previous 7 bits add up to an odd number, and 0 if the previous 7 bits add up to an even number.

Mark parity will set every eighth bit to 1 and Space parity every bit to 0.

Stop Bits Factory default: 1

This specifies the number of stop bits sent for each transmitted character.

Flow Control Factory default: Both

This option specifies the type of flow control used by the line port to communicate readiness to transmit or receive data from the auxiliary port device.

None

No flow control.

Input

XON/XOFF on received data.

Output

XON/XOFF on transmitted data.

Both

XON/XOFF on transmitted and received data.

Hardware

RTS/CTS hardware flow control.

Enable Bidirectional Factory default: Checked

The setting of this option determines whether data from the auxiliary port device can be transmitted to the host as well as received from the host through the TeemTalk session.

Open at Session Startup Factory default: Unchecked

Selecting this option will cause the Aux port to be opened as soon as the TeemTalk session is started.

98