This option applies to the WY-50+, WY-60 and all the TVI emulations. It determines whether or not more than one page of display memory can be accessed. When checked, all pages will be accessible. See also the Auto page option.

Note that the TVI emulations support two pages of 24 lines each when this and the Auto page options are selected, regardless of the Screen lines and Page size settings.

Screen lines Factory default: 24

This option applies to the WY-50+ and WY-60 emulations and specifies the number of data lines displayed on the screen below the status line. Note that the other emulations only support 24 lines and a label line.

Screen lines

Effect on display

 

 

24

24 data lines and a label line at the bottom

 

 

25

25 data lines but no label line

 

 

42

42 data lines and a label line at the bottom

 

 

43

43 data lines but no label line

Screen columns Factory default: 80

This option enables you to specify a display width of 80 or 132 columns.

Page size

Factory default: 1 x Lines

This option applies to the WY-50+ and WY-60 emulations and specifies the size of a page in display memory in multiples of the Lines setting. Note that the other emulations only support 1 x Lines.

The 1 + Rest setting will divide the display memory into two pages, the first containing the number of lines specified by the Lines option, the second containing all the remaining lines.

NOTE: Changing the page format will cause the entire display memory to be cleared, the cursor will move to the home position and the scroll margin will be reset.

Attribute type Factory default: Page

The setting of this option determines whether display attributes are active to the end of the line or the end of the page. The Character setting only applies to the WY-60 emulation and causes attributes to only apply to characters written to the screen. The WY-50, ADDS A2 and HZ 1500 emulations only support the Page setting.

Status line

Factory default: Standard

This option applies to all emulations and enables you to specify the type of status line displayed at the top of the screen, or remove it from the display.

Setup Options 225