Configuring the | Configuration Screens |
|
|
Other models of modems may also work with the
Within the
This screen allows you to configure basic modem operation. Use the Advanced button to display additional modem configuration options.
Field/Button | Description |
Enable Dial Backup | Click this checkbox to enable dial backup operation. By default, this |
| operation is disabled. |
|
|
AT Initialization String | Enter the initialization string for your modem. This string is sent to the |
| modem every time dial backup starts. This string is sent to the modem |
| every time dial backup starts. Up to 128 characters are accepted in |
| this field. At a minimum, you must specify at least the command AT |
| here; you cannot have a blank initialization string. The |
| looks for the response to the attention command to determine the |
| modem's current state. Also, the |
| You must include the command V0 in your initialization string to |
| require a numeric response from the modem. |
| Consult the manufacturer's documentation for your specific modem to |
| determine the command set being used and what commands are |
| accepted by the modem. Reset to Default can be used to reset the |
| initialization string to the default US Robotics modem setting of: |
| ATE0V0Q0&C1&D2&K0&M4X4 |
| If you are using a Hayes or ZOOM modem, the initialization string |
| should be set to: |
| ATE0V0Q0&C1&D2&K3&Q5W2 |
AT Hang Up String | This is similar to the initialization string, except this command string is |
| sent to the modem to cause it to hang up. Enter the hang up string for |
| your modem. Up to 20 characters are accepted in this field. Consult |
| the manufacturer's documentation for your specific modem to |
| determine the command set being used and what commands are |
| accepted by the modem. Reset to Default can be used to reset the |
| hang up string to the default setting of “ATH0”. This default can be |
| used for all supported modem types. Any additional commands you |
| want to add to the string should be placed after the AT and before the |
| H0. Any commands entered as part of the Hang Up string are |
| automatically prefixed with “+++”. |
|
|
Enable Primary Dial | Click this checkbox to enable the primary dial string. This is the first |
| host processor that the modem will attempt to contact in the event of |
| an Ethernet outage. |
|
|
Primary AT Dial String | Enter any commands and the phone number to dial in order for the |
| modem to establish contact with the primary host processor. Up to 32 |
| characters are allowed in this field. This string must begin with ATDT |
| (or ATDP for pulse dialing). |
|
|