Title: C74AMST CreationDate: 06/23/93 17:09:07
6.
The SCSI FIXED/REMOVAL DRIVE MENU appears. This menu lists 7 possible test options. If your installation has no hard disk drives, only Test Options 0, 1, 2, 3, and 4 appear on this menu. The individual tests are described briefly below the figure of the menu.
Adapter Diagnostics Three pass/fail tests are run on the SCSI controller to check ROM, RAM, and the SCSI data bus.
Device Diagnostics This function issues the Device Diagnostics command to the selected device. If the device is a removable media type, it prompts for media to be inserted. If the command completes successfully, the selected device is installed and functioning properly.
Test Unit Ready This command is issued to each device to check that the device is online and ready to accept command requests.
Get Device Status If either the Test Unit Ready, Read, or Read/Write test resulted in an error condition, you should run Get Device Status to isolate the specific problem causing the error condition.
Read Test This test issues Read commands from the beginning to the end of the entire drive to verify that the drive processes them properly.