3745 and Service Processor Maintenance
Service Processor Maintenance Using an SRC Sequence Number
The service processor console should be logged ON. If it is not, go to “Console Use for Maintenance” on
page 1-1 for logging ON and return here.
1. On the MOSS-E View window, double click on the service processor icon.
2. The Service Processor Menu window is displayed.
3. Click on the Problem management option.
4. Double-click on the Manage Alarms/Errors/Events (SRCs) option.
5. Select the Alarm option then click on OK.
6. On the next window, double-click on the alarm which has the SRC number that you want.
7. A FRU or a list of FRUs with the FRU location is displayed.
8. Record this FRU list with each card fault probability.
9. Go to "Service Processor Problem Determination" in the corresponding
Service Processor Installation
and Maintenance
manual.
Chapter 1. START: How to Begin Troubleshooting 1-57