Disabling Procedures
à
@ð
CUSTOMER ID: 3745 SERIAL NUMBER:
CCU-A SELECTED PROCESS MOSS-ONLINE X71:ð2ð415
X72:ðððð85
RUN-REQ
-------------------------------------------------------------- ð3/ð1/87 ð1:22
FUNCTION ON SCREEN: ONLINE DIAGS
GROUP :ADP# :LINE :
1 ALL :
2 CCU : : :
3 IOCB: 1- 4: :
4 CA : 1- 8: :
5 TSS : 1-32: ð-31:
6 TRSS: 1- 2: 1- 2:
7 HTSS: 1- 8: :
8 OLT : 1- 8: :
9 ESS : 1- 8: :
OPT= Y IF MODIFY :
OPTION REQUIRED :
: ENTER REQUEST ACCORDING TO THE DIAG MENU
: DIAG==>(A) ADP#==>(B) LINE==>(C)
===>
F1:END F2:MENU2 F3:ALARM F6:QUIT
á
ñ

(A) Enter 5here for TSS diagnostics or 7 for HPTSS.

(B) Enter the number of the suspected adapter here.

(C) Enter the number of the line (00-15) or (00-31) here.

Figure 1-10. TSS/HPTSS Diagnostic Selection Screen

1-72 3745 Models 130 to 17A: MIP