3745 Control Panel
Request Local Console
1. Using Function, scroll till the value is 3,
Request local console.
2. PressValidate.
A message is sent to inform the remote/alternate
or RSF console customer that the local console
customer wants to log on at the local console.
Force Local Console
1. Using Function, scroll till the value is 4, Force
local console.
2. PressValidate.
The link to the remote/alternate or RSF console is
disconnected to allow the local console customer
to log on.
Panel Test and Console LinkTests
See the separate detailed procedures in
Chapter 3, “How to Run 3745 Diagnostics” on
page 3-1.
Load from Diskette
1. Insert diskette 1 into the diskette drive.
2. Close the diskette drive (by turning or pulling
the door latch).
3. Two options are available:
Option A:
1. Using Service Mode, scroll till the value is 0,
Normal mode.
2. PressValidate.
3. Using Function, scroll till the value is 9, Load
from diskette.
4. PressValidate.
A general reset, MOSS IML, CCU IPL, and a
scanner IML is executed and the CLDP is loaded.
Option B:
1. Using Service Mode, scroll till the value is 1,
Maintenance 1 mode.
2. PressValidate.
3. Using Function, scroll till the value is 9, Load
from diskette.
4. PressValidate.
A MOSS reset followed by a MOSS IML will be
executed.
Loop on MOSS Diagnostics
1. Using Service Mode, scroll till the value is 1,
Maintenance 1 mode.
2. PressValidate.
3. Using Function, scroll till the value is A, Loop
on MOSS diagnostics.
4. PressValidate.
The diagnostic MOSS code loops until an error is
detected and the error code is displayed.
Press Exit to terminate the diagnostic loop.
Display Stacked Errors
1. Using Service Mode, scroll till the value is 1,
Maintenance 1 mode.
2. PressValidate.
3. Using Function, scroll till the value is B,
Display stacked errors
4. PressValidate.
5. Using Service Mode, scroll till the value is A,
Display the First Stacked Error
6. PressValidate.
7. Using Service Mode, scroll till the value is B,
Display the Second Stacked Error
8. PressValidate.
9. Similary stacked errors 3 and 4 are displayed
by selecting Service Mode C and D.
Chapter 1. START: How to Begin Troubleshooting 1-83