3745 MAPs
009 (continued)
Is the 3745 still powered ON?
Yes No
010
Go to “CE Leaving Procedure” on
page 4-102.
011
Power the 3745 OFF as follows:
Set the power control to local mode:
Using Power Control, scroll till the
value is 3.
Press Validate.
Press Power Off.
Turn the CB1 OFF.
Re-install the PCC card.
Exchange the MCC card (01A-X0H). Refer to
Figure 4-9 on page 4-11.
Turn the CB1 ON.
Press Power On Reset.
Set the power control to network mode.
Using Power Control, scroll till the value is
2.
Press Validate.
Select the IFT diagnostics and run routine
AT05.
Is the 3745 still powered ON?
Yes No
012
Go to “CE Leaving Procedure” on
page 4-102.
013
Power the 3745 OFF as follows:
Set the power control to local mode:
Using Power Control, scroll till the
value is 3.
Press Validate.
Press Power Off.
Re-install the MCC card (01A-X0H).
Exchange the PUC card (01G-V).
Set the power control to network mode.
Using Power Control, scroll till the value is
2.
Press Validate.
Select the IFT diagnostics and run routine
AT05.
(Step 013 continues)
013 (continued)
Is the 3745 still powered ON?
Yes No
014
Go to “CE Leaving Procedure” on
page 4-102.
015
Re-install the PUC card (01G-V).
You have gone through the entire procedure and
the problem is still present. Contact your support
structure for further assistance.
Chapter 2. Map for FRU Isolation 2-29