3745 Panel Codes

Table 1-5 (Page 2 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
010 Machine powered OFF because power supply or blower
faults
Use the function 'B' to display the four
stacked errors. Refer to “Display
Stacked Errors” on page 1-83.
011 to 02F Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
030 Problem detected with Power supply Fan Go to “Power MAP 3920: Air Flow
Detector Fault” on page 2-19
031 Problem detected with MOSS and basic board Fan
032 Problem detected with MOSS and basic board Fan
033 to 04F Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
050 INITIAL MOSS PROCESSOR RESET STATE NOT OK Exchange the FRU group 1
.
051 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
052 INITIAL MOSS PROCESSOR STATE OK
(PROGRESSION CODE) Progression code. If permanently displayed, exchange
the FRU group 2
053 UNEXPECTED LEVEL 0 INTERRUPT PRESENT IN
THE IOIRV. Exchange the FRU group 3
054 UNEXPECTED LEVEL 1 INTERRUPT PRESENT IN
THE IOIRV.
055 UNEXPECTED LEVEL 2 INTERRUPT PRESENT IN
THE IOIRV. Exchange the FRU group 4
056 UNEXPECTED LEVEL 3 INTERRUPT PRESENT IN
THE IOIRV. Exchange the FRU group 3
057 UNEXPECTED LEVEL 4 INTERRUPT PRESENT IN
THE IOIRV. Exchange the FRU group 3
058 UNEXPECTED LEVEL 5 INTERRUPT PRESENT IN
THE IOIRV. Exchange the FRU group 7
059 UNEXPECTED LEVEL 6 OR 7 INTERRUPT PRESENT
IN THE IOIRV. Go to “MAP 3210: MOSS Control
Panel Code 059” on page 2-4
05A MOSS PROCESSOR CONDITIONS CODES NOT OK Exchange the FRU group 2
05B Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
05C MOSS PROCESSOR CACHE NOT OK Exchange the FRU group 2
05D MOSS PROCESSOR INSTRUCTION TEST PART 1
NOT OK
05E Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
05F ROS CHECKSUM NOT OK Exchange the FRU group 2
060 ROS BAD PARITY LOCATION NOT DETECTED
061 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
062 EIRV DOES NOT REPORT FORCED ERRORS Exchange the FRU group 2
063 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
070 PIO BUS TEST DID NOT RUN COMPLETELY Exchange the FRU group 1
.
071 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os.
072 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA I/Os. Exchange the FRU group 7
073 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC AND DFA I/Os. Exchange the FRU group 6
074 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MCCU OR MCAD
I/Os ON MCC Exchange the FRU group 3
075 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os AND ON
MCCU OR MCAD I/Os ON MCC.
Exchange the FRU group 1
.
1-16 3745 Models 130 to 17A: MIP