3745 Panel Codes

Table 1-5 (Page 5 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0DFñIOIRV REGISTER IS X'00' IN TEST 2 NO INTER-
RUPT REQUESTED
Exchange the FRU group 15
0E0ñCHIO TRANSFER KO
0E1ñ
ADAPTER IN BUSY STATE IN TEST 4 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RUN DIAGNOSTIC
COMMAND TEST
0E2ñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO RUN DIAGNOSTIC
COMMAND TEST
0E3ñDIFFERENT CONTENTS IN THE FIRST AND THE
SECOND PART OF THE SECTOR BUFFER RUN
DIAGNOSTIC COMMAND TEST Exchange the FRU group 15
0E4ñERROR IN SSB BYTE 0 RUN DIAGNOSTIC
COMMAND TEST Exchange the FRU group 21
0E5ñERROR IN SSB BYTE 1 AND 2 RUN DIAGNOSTIC
COMMAND TEST Exchange the FRU group 15
0E6ñADAPTER IN BUSY STATE IN TEST 5 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE DRIVES INITIALIZATION
Exchange the FRU group 16
0E7ñIOIRV REGISTER IS X'00' IN TEST 5 NO INTER-
RUPT RECEIVED DRIVES INITIALIZATION
0E8ñEIRV REGISTER IS NOT X'00' IN TEST 5 DRIVES
INITIALIZATION
0E9ñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
0EAñ
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND
BEFORE RECALIBRATE TEST
Exchange the FRU group 16
0EBñIOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED SEEK COMMAND BEFORE
RECALIBRATE TEST
0EDñ
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
TEST
0EEñIOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND TEST
0EFñEIRV REGISTER IS NOT X'00' IN TEST 6 RECALI-
BRATE COMMAND TEST Exchange the FRU group 16
0F0 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0F1ñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
RECALIBRATE COMMAND TEST Exchange the FRU group 16
0F2ñNO CYLINDER ZERO IN SSB BYTE0 BIT 7 RECALI-
BRATE COMMAND TEST
0F3ñERROR IN SSB BYTE 0 RECALIBRATE COMMAND
TEST
Exchange the FRU group 16
0F4ñERROR IN SSB BYTE 1 AND 2 RECALIBRATE
COMMAND TEST
0F5ñADAPTER IN BUSY STATE IN TEST 7 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ ID COMMAND TEST
0F6ñIOIRV REGISTER IS X'00' IN TEST 7 NO INTER-
RUPT RECEIVED READ ID COMMAND TEST
Chapter 1. START: How to Begin Troubleshooting 1-19