Diagnostics
How to Select Diagnostics
à
@ð
CUSTOMER ID: 3745 SERIAL NUMBER:
CCU-A SELECTED PROCESS MOSS-OFFLINE X71:ð2ð415
X72:ðððð85
-------------------------------------------------------------- ð3/ð7/87 ðð:21
FUNCTION ON SCREEN: OFFLINE DIAGS
GROUP :ADP# :LINE :
1 ALL : : :
2 CCU : A- B: :
3 IOCB: 1- 4: :
4 CA : 1-16: :
5 TSS : 1-32: ð-31:
6 TRSS: 1- 6: 1- 2:
7 HTSS: 1- 8: :
8 OLT : 1-16: : DIAGNOSTICS INITIALIZATION
9 ESS : 1- 8: :
Xð CBA : 1- 2:
OPT= Y IF MODIFY :
OPTION REQUIRED :
: ENTER REQUEST ACCORDING TO THE DIAG MENU
: DIAG==> ADP#==> LINE==> OPT==>
===>
F1:END F2:MENU2 F3:ALARM
á
ñ
Figure 3-5. How to Select Diagnostics
After entering ODG or CDG in Menu 3, the diag-
nostic menu is displayed. See Figure 3-5.
Four input fields are available in this menu:
DIAG==> Diagnostic group (1-10), IFT,
section, or routine to be run.
Example:
2 (full set of CCU IFTs)
K (section K of IOC diagnostics)
AC01 (specific routine of CCU diagnos-
tics)
Note
If you select 3 (IOCB) with no adapter
installed, a warning will be reported (invalid
request).
ADP#==> Adapter number
LINE==> Line number for TSS, TRSS,
HPTSS, or ESS. The line number is obtained
from the LID function (in Menu 1) by entering
the line address.
OPT==> Y to display the option menu.
If the ALL option is entered, diagnostics will be
run on all adapters in the CDF and disconnected
from the NCP.
Note
Do not select ALL when a channel adapter
and an Ethernet adapter are installed. An error
will be reported on the Ethernet adapter.
Type your request in the input fields and press
SEND.
If OPT==>Y is entered, the option menu is dis-
played. See Figure 3-6 on page 3-11. If not, the
diagnostic is started and the diagnostic result is
displayed in this frame.
3-10 3745 Models 130 to 17A: MIP