3745 Panel Codes

Table 1-5 (Page 10 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
17E Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
17F COMPLETION OF ROS PART OF MOSS DIAGNOS-
TICS Progression code. If permanently displayed, exchange
the FRU group 24
180 ENTRY INTO RAM PART OF MOSS DIAGNOSTICS
Progression code. If permanently displayed, exchange
the FRU group 25
181ñCURRENT PROGRAM LEVEL NOT AS EXPECTED
(SHOULD HAVE BEEN 6) Exchange the FRU group 25
182 RAM DIAG CONTROLLER HAS FULL CONTROL
Progression code. If permanently displayed, exchange
the FRU group 25
183 to 187 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
188 CONTROL LOST DURING INSTRUCTION TEST PART
2Exchange the FRU group 25
189ñMOSS PROCESSOR INSTRUCTION TEST PART 2
NOT OK
18A MOSS PROCESSOR INSTRUCTION TEST PART 2
SUCCESSFULLY RUN Progression code. If permanently displayed, exchange
the FRU group 25
18B Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
18C CONTROL LOST DURING TOD ADAPTER TEST Exchange the FRU group 6
18D END OF TOD TEST (SUCCESSFUL OR NOT)
Progression code. If permanently displayed, exchange
the FRU group 2
18E to 18F Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
190 START OF MCC TEST Progression code. If permanently displayed, exchange
the FRU group 9
191ñHARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 1 Exchange the FRU group 5
192ñERROR IN PCA 1 TEST ASYNCHRONOUS Exchange the FRU group 26
193ñUNEXPECTED LEVEL 0 INTERRUPT DURING PCA1
TEST Exchange the FRU group 5
194ñERROR IN PCA 1 INTERNAL WRAP ASYNCHRO-
NOUS TEST. Exchange the FRU group 26
195ñUNEXPECTED LEVEL 0 INTERRUPT DURING PCA1
TEST Exchange the FRU group 6
196ñHARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 2 Exchange the FRU group 5
197ñERROR IN PCA 2 TEST ASYNCHRONOUS Exchange the FRU group 26
198ñUNEXPECTED LEVEL 0 INT. DURING PCA2 TEST Exchange the FRU group 5
199ñERROR IN PCA 2 INTERNAL WRAP ASYNCHRO-
NOUS TEST. Exchange the FRU group 26
19AñUNEXPECTED INT. (<> LEVEL 0) IN PCA2 TEST Exchange the FRU group 6
19BñHARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 3 Exchange the FRU group 5
19CñERROR IN PCA 3 TEST SYNCHRONOUS Exchange the FRU group 26
19DñUNEXPECTED LEVEL 0 INT. DURING PCA3 TEST Exchange the FRU group 5
19EñERROR IN PCA 3 INTERNAL WRAP SYNCHRONOUS
TEST. Exchange the FRU group 26
19FñUNEXPECTED INT. (<> LEVEL 0) IN PCA3 TEST Exchange the FRU group 5
1A0 WRAP BLOCK DOES NOT SEEM TO BE PRESENT
ON LOCAL PORT , OR SIGNALS TESTED ARE NOT
OK. Exchange the FRU group 27
1A1 LOCAL CONSOLE CABLE DOWN (WHEN WRAP
BLOCK INSTALLED) Exchange the FRU group 28
1A2 LOCAL CONSOLE PCA ERROR Exchange the FRU group 26
1A3 WRAP BLOCK DOES NOT SEEM TO BE PRESENT
ON REMOTE PORT , OR SIGNALS TESTED ARE
NOT OK. Exchange the FRU group 27
1-24 3745 Models 130 to 17A: MIP