3745 Panel Codes

Table 1-5 (Page 4 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0ADñNO SINGLE ERROR CORRECTION IN TEST 3 Exchange the FRU group 13
0AEñBAD SINGLE ERROR CORRECTION IN TEST 3
0AF Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0B0ñNO DOUBLE ERROR DETECTION IN TEST 3 Exchange the FRU group 13
0B1ñDIFFERENT LOADED AND STORED CONTENTS IN
TEST 4 Exchange the FRU group 11
0B2ñRECONFIGURE BIT IN TOD ADAPTER CAN NOT BE
SET IN TEST 5 Exchange the FRU group 13
0B3 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0B4ñDIFFERENT LOADED AND STORED CONTENTS IN
TEST 7 Exchange the FRU group 11
0B5ñDOUBLE UNCORRECTABLE ERROR IN TEST 6 Exchange the FRU group 13
0B6ñENABLE VALID OPTION KO IN TEST 9 Exchange the FRU group 12
0B7ñEIRV REGISTER IS NOT X'00' IN TEST 9 Exchange the FRU group 13
0B8 to 0BE Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0BF MOSS MEMORY TEST EXIT CODE Progression code. If permanently displayed, exchange
the FRU group 2
0C0 PROBLEM IN ROS MAINLINE CONTROLLER INITIAL-
IZATION Exchange the FRU group 14
0C1 CONTROL LOST AFTER INITIALIZING THE ROS
MAINLINE CONTROLLER Exchange the FRU group 2
0C2 CONTROL LOST DURING PSV SWAP TEST Exchange the FRU group 13
0C3ñSTORAGE CHECK (WHEN ACCESSING THE REG-
ISTER SPACE) Exchange the FRU group 11
0C4ñSCHEDULED PROGRESSION NOT PERFORMED
DURING THE PSV SWAP TEST Exchange FRU group 13
0C5ñCACHE IN/CACHE OUT OPERATION NOT SUC-
CESSFUL
0C6 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0C7 PSV SWAP TEST SUCCESSFUL Progression code. If permanently displayed, exchange
the FRU group 2
0C8 to 0CF Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0D0ñDISK ADAPTER TEST ENTRY CODE Progression
code. If permanently displayed, exchange
the FRU group 2
0D1ñEIRV REGISTER IS NOT X'00' IN TEST 1 Exchange the FRU group 54
0D2ñIOIRV REGISTER IS NOT X'00' IN TEST 1 Exchange the FRU group 15
0D3ñADAPTER NOT IN BUSY STATE OR NOT ENABLE
BSTAT BITS 0,1 ARE NOT B'10' IN TEST 1
0D4 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0D5ñADAPTER NOT IN IDLE STATE IN TEST 1 BSTAT
BITS 0,1 ARE NOT B'00' Exchange the FRU group 15
0D6ñDIFFERENT LOADED AND READ CONTENTS IN
TEST 2
0D7ñREGISTER NOT RESET AFTER A RESET COMMAND
IN TEST 2
Exchange the FRU group 15
0D8ñINVALID PIO COMMAND
0D9ñEIRV REGISTER IS NOT X'00' IN TEST 2
0DAñIOIRV REGISTER IS NOT X'00' IN TEST 2
0DBñADAPTER IN BUSY STATE IN TEST 1 BSTAT BITS
0,1 ARE NOT B'00'
Exchange the FRU group 15
0DCñEIRV REGISTER IS NOT X'00' IN TEST 3
0DDñIOIRV REGISTER IS NOT X'00' IN TEST 2
0DEñEIRV REGISTER IS NOT X'00' IN TEST 3
1-18 3745 Models 130 to 17A: MIP