Disabling Procedures
005 (continued)
Did the diagnostics run without error?
Yes No
006
Go to “Diagnostic and Exchange Result
Analysis 0000” on page 4-99.
007
Note their positions and remove the modem or
line cables from the LIC.
If the LIC is type 1 or 4, install the wrap plug
(PN 65X8927) on the uppermost socket. See
Figure 1-17 on page 1-76 and Figure 1-14 on
page 1-75.
If the LIC is type 3, install the LIC wrap cable
(PN 65X8928) between the two sockets. See
Figure 1-17 on page 1-76 and Figure 1-15 on
page 1-75.
If the LIC is type 5 or 6, unplug the line cable at
the customer wall frame and install the wrap
plug (PN 11F4815) on the uppermost socket of
the cassette. See Figure 1-18 on page 1-77
and Figure 1-16 on page 1-76.
Is the LIC type 1, 3, or 4?
Yes No
008
Using the LID function, enter the line
address in the input area of the displayed
screen and record the line number dis-
played on the next sceen.
Run only the RH59 routine of the concur-
rent TSS diagnostics using the number of
the suspected adapter, and the line
number recorded above, refer to
Figure 1-10 on page 1-72.
If necessary, refer to “How to Run Internal
Function Tests” on page 3-9.
Did the diagnostics run without error?
Yes No
009
Go to “Diagnostic and Exchange
Result Analysis 0000” on page 4-99.
010
Change the wrap plug to the other socket,
if any (LIC type 5).
Rerun the RH59 routine of the TSS diag-
nostics.
(Step 010 continues)
010 (continued)
Did the diagnostics run without error?
Yes No
011
Go to “Diagnostic and Exchange
Result Analysis 0000” on page 4-99.
012
No trouble was found with this LIC.
Remove the wrap plug.
Go to “Diagnostic and Exchange Result
Analysis 0000” on page 4-99.
013
Using the LID function, enter the line address in
the input area of the displayed screen and
record the line number displayed on the next
screen.
Run only the RC01 routine of the concurrent
TSS diagnostics, using the number of the sus-
pected adapter, and the line number recorded
above. Refer to Figure 1-10 on page 1-72.
If necessary, refer to “How to Run Internal
Function Tests” on page 3-9.
Did the diagnostics run without error?
Yes No
014
Go to “Diagnostic and Exchange Result
Analysis 0000” on page 4-99.
015
Is the LIC type other than 3?
Yes No
016
Go to Step 024 on page 1-71.
017
Is the LIC type 1 or 4A?
Yes No
018
No trouble was found with this LIC.
Remove the wrap plug and reconnect the
modem cable.
Go to “Diagnostic and Exchange Result
Analysis 0000” on page 4-99.
1-70 3745 Models 130 to 17A: MIP