3745 Panel Codes

Table 1-5 (Page 7 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
11DñERROR IN SSB BYTE 1 AND 2 READ/WRITE A
SECTOR COMMAND
Exchange the FRU group 16
11Eñ
ADAPTER IN BUSY STATE IN TEST 10 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE A FULL
TRACK COMMAND
11FñIOIRV REGISTER IS X'00' IN TEST 10 NO INTER-
RUPT RECEIVED READ/WRITE A FULL TRACK
COMMAND
120ñEIRV REGISTER IS NOT X'00' IN TEST 10
READ/WRITE A FULL TRACK COMMAND
121ñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE A FULL
TRACK COMMAND
Exchange the FRU group 16
122ñDIFFERENT WRITTEN AND READ TRACKS
READ/WRITE A FULL TRACK COMMAND
123ñERROR IN SSB BYTE 0 READ/WRITE A FULL
TRACK COMMAND
124ñERROR IN SSB BYTE 1 AND 2 READ/WRITE A FULL
TRACK COMMAND
125ñ
ADAPTER IN BUSY STATE IN TEST 11 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE NO DATA
COMMAND
Exchange the FRU group 16
126ñIOIRV REGISTER IS X'00' IN TEST 11 NO INTER-
RUPT RECEIVED READ/WRITE NO DATA
COMMAND
127ñEIRV REGISTER IS NOT X'00' IN TEST 11
READ/WRITE NO DATA COMMAND
128ñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE NO DATA
COMMAND
129ñDIFFERENT WRITTEN AND READ SECTORS
READ/WRITE NO DATA COMMAND
Exchange the FRU group 16
12AñERROR IN SSB BYTE 0 READ/WRITE NO DATA
COMMAND
12BñERROR IN SSB BYTE 1 AND 2 READ/WRITE NO
DATA COMMAND
12Cñ
ADAPTER IN BUSY STATE IN TEST 12 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ CHECK/WRITE
VERIFY COMMAND
12DñIOIRV REGISTER IS X'00' IN TEST 12 NO INTER-
RUPT RECEIVED READ CHECK/WRITE VERIFY
COMMAND
Exchange the FRU group 16
12Eñ EIRV REGISTER IS NOT X'00' IN TEST 12 READ
CHECK/WRITE VERIFY COMMAND
12FñDATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ CHECK/WRITE
VERIFY COMMAND
130ñERROR IN SSB BYTE 0 READ CHECK/WRITE
VERIFY COMMAND
131ñERROR IN SSB BYTE 1 AND 2 READ CHECK/WRITE
VERIFY COMMAND
Exchange the FRU group 16
132ñDIFFERENT WRITTEN AND READ SECTORS READ
CHECK/WRITE VERIFY COMMAND
133ñADAPTER IN BUSY STATE IN TEST 13 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE ECC CORRECTION TEST
134ñIOIRV REGISTER IS X'00' IN TEST 13 NO INTER-
RUPT RECEIVED ECC CORRECTION TEST
Chapter 1. START: How to Begin Troubleshooting 1-21