3745 Panel Codes

Table 1-5 (Page 3 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
076 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA I/Os AND ON
MCCU OR MCAD I/Os ON MCC. Exchange the FRU group 8
077 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os AND ON
DFA I/Os AND ON MCCU OR MCAD I/Os ON MCC. Exchange the FRU group 6
078 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON PCA'S I/Os ON MCC Exchange the FRU group 3
079 SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC AND PCA'S I/Os
ON MCC
Exchange the FRU group 1
.
07A SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA AND PCA'S I/Os
ON MCC Exchange the FRU group 8
07B SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os , DFA I/Os
AND PCA'S I/Os ON MCC. Exchange the FRU group 6
07C SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MCC I/Os
(MCCU,MCAD AND PCA'S). Exchange the FRU group 3
07D SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC AND MCC I/Os. Exchange the FRU group 1
.
07E SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA AND MCC I/Os. Exchange the FRU group 8
07F SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST ERRORS WERE DETECTED ON ALL
ADAPTERS
Exchange the FRU group 1
.
080 to 096 Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
097 PIO TEST PART 1 SUCCESSFUL PROBLEM IN PIO
BUS TEST PART 2 Exchange the FRU group 9
098ñPIO TEST PART 2 NOT SUCCESSFUL Exchange the FRU group 5
099 PIO TEST PART 2 SUCCESSFUL Progression code. If permanently displayed, exchange
the FRU group 2
09A to 09C Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
09D PROBLEM WITH PCC Exchange the FRU group 12
09E
INFORMATION DEFINING THE ORIGIN OF THE
ACTIVATION OF THE MOSS DIAGNOSTICS IS NOT
VALID. (RUN THE PANEL TEST TO CHECK THE
CONTROL PANEL).
Exchange the FRU group 10
09F CONTROL LOST IN THE MAINLINE CONTROLLER
AFTER CHECKING THE REQUEST Exchange the FRU group 2
0A0 MOSS STORAGE TEST ENTRY CODE Progression
code. If permanently displayed, exchange
the FRU group 2
0A1ñEIRV REGISTER IS NOT X'00' IN TEST 1 Exchange the FRU group 2
0A2ñEIRV REGISTER IS NOT X'00' IN TEST 2 Exchange the FRU group 11
0A3ñDISABLE THE VALID OPTION KO IN TEST 1 Exchange the FRU group 12
0A4ñRECONFIGURE BIT IS ALWAYS 'ON' IN TOD
ADAPTER Exchange the FRU group 13
0A5ñADDRESS NOT INCREMENTED IN TEST 2 Exchange the FRU group 13
0A6ñDIFFERENT LOADED AND STORED CONTENTS IN
TEST 2 Exchange the FRU group 11
0A7ñINVALID ADDRESS IN THE ROS IN TEST 2 Exchange the FRU group 13
0A8ñINVALID ADDRESS AFTER 512K OR 1MEG IN TEST
2Exchange the FRU group 13
0A9ñNO MEMORY LOCATION WITHOUT ERROR IS
FOUND IN TEST 2 Exchange the FRU group 11
0AAñEIRV REGISTER IS NOT X'00' IN TEST 4 Exchange the FRU group 13
0AB to 0AC Unused Go to “MAP 3220: Undefined Panel
Message” on page 2-5
Chapter 1. START: How to Begin Troubleshooting 1-17