3745 Panel Codes

Table 1-5 (Page 15 of 33). Panel Codes. An

ñ
following a panel code denotes that the code should 'Blink'.
Panel
Code Definition Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
A80ñMoss level 0 error detection; SWAD; PIO; Timeout;
Overrun
Exchange the FRU group 5
A81ñMoss level 0 error detection; SWAD; PIO; Timeout;
Adapter not detected
A82ñMoss level 0 error detection; SWAD; PIO; Timeout;
Adapter failure
A83ñMoss level 0 error detection; SWAD; PIO; time out;
Multiple bits detected in Stat register
A84ñMoss level 0 error detection; MCAD; Adapter is 'down'
Exchange the FRU group 5
A85ñMoss level 0 error detection; MCAD; PIO; Bus check;
Inbound parity
A86ñMoss level 0 error detection; MCAD; PIO; Bus check;
Adapter failure
A87ñMoss level 0 error detection; MCAD; PIO; Bus check;
Adapter not detected
A88ñMoss level 0 error detection; MCAD; PIO; time out;
Invalid command
Exchange the FRU group 5
A89ñMoss level 0 error detection; MCAD; PIO; time out; Out-
bound parity check
A8AñMoss level 0 error detection; MCAD; PIO; time out;
Adapter not detected
A8BñMoss level 0 error detection; MCAD; PIO; time out;
Adapter failure
A8CñMoss level 0 error detection; MCAD; PIO; time out; Mul-
tiple bits detected in Stat reg Exchange the FRU group 5
A8DñMoss level 0 error detection; DFA; Adapter is 'down' If loading from diskette (function 9
from the control panel) then exchange
the FRU group 45; if loading from
HDD then exchange the FRU group
46
A8EñMoss level 0 error detection; DFA; CHIO Bus check
A8FñMoss level 0 error detection; DFA; CHIO time out
A90ñMoss level 0 error detection; DFA; CHIO; Storage ECC
error; Register space parity during main store. Exchange the FRU group 43
A91ñMoss level 0 error detection; DFA; CHIO; Storage ECC
error; Multiple bits in DIV Register
A92ñMoss level 0 error detection; DFA; CHIO; Storage ECC
error; No bits active in DIV Register
Exchange the FRU group 15. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
A93ñMoss level 0 error detection; DFA; CHIO; Exception;
Operation
exception; CHCV Reg invalid
A94ñMoss level 0 error detection; DFA; CHIO; Exception;
Register
precision; CHP Reg bits 0-7 are not zero
A95ñMoss level 0 error detection; DFA; CHIO; Exception;
Specification exception with invalid address on main
store data access
A96ñMoss level 0 error detection; DFA; CHIO; Exception;
Address exception on main store data access Exchange the FRU group 15. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
A97ñMoss level 0 error detection; DFA; CHIO; Exception;
Multiple bits in DIV Register
A98ñMoss level 0 error detection; DFA; CHIO; Exception; No
bits active in DIV Register
A99ñMoss level 0 error detection; DFA; CHIO; Internal
check; Cache parity check If loading from diskette (function 9
from the control panel) then exchange
the FRU group 45; if loading from
HDD then exchange the FRU group
46
A9AñMoss level 0 error detection; DFA; CHIO; Internal
check; Invalid address on CHP Reg access
A9BñMoss level 0 error detection; DFA; CHIO; Internal
check; Multiple bits in DIV Register
A9CñMoss level 0 error detection; DFA; CHIO; Multiple bits
detected in EIRV reg
Chapter 1. START: How to Begin Troubleshooting 1-29