Performing a new system backup

__ 1. Perform a normal IPL:

No LPAR

LPAR Primary Partition

LPAR Secondary Partition

Perform the following:

Perform the steps in the No

Perform the steps in the No

a. Make sure that the

LPAR column after verifying

LPAR column (set partitions

that all secondary partitions

to B Normal mode, and then

system is set to B and

are powered down.

power down and perform an

Normal (N) mode before

 

IPL on the partitions), using

performing the power

For information about

appropriate LPAR service

down and subsequent

powering down a system,

tool steps, only after

IPL of the system.

see the Powering down a

successfully performing a

b. Once the system is set to

system with logical

normal IPL of the primary

B and Normal mode,

partitions topic in the

partition.

follow these steps:

Information Center under

 

 

 

 

1)

Type PWRDWNSYS on

Systems Management ->

For instructions on setting

 

the command line

Logical partitions ->

the IPL mode, powering

 

and prompt on the

Managing logical partitions

down, and performing an

 

command (Press F4). -> Restarting and powering

IPL on secondary partitions,

2)

Make sure that you

down a system with logical

see the Restarting and

partitions.

powering down a system

 

select these options

 

 

with logical partitions

 

for the PWRDWNSYS

 

 

 

topic in the Information

 

command:

 

 

 

Center under Systems

 

v For How to end,

 

 

 

Management -> Logical

 

*CNTRLD

 

 

 

partitions -> Managing

 

v For Delay time, if

 

 

 

logical partitions.

 

*CNTRLD, 3600

 

 

 

(use the default

 

 

 

value, in seconds,

 

 

 

or the value that

 

 

 

you consider

 

 

 

appropriate given

 

 

 

your software and

 

 

 

system settings)

 

 

vFor Restart after power down, *YES

vFor IPL Source,

*PANEL

SRC A900 2000 should not appear on the control panel when the IPL completes. If SRC A900 2000 does appear and you are using Operations Console, you must perform an IPL in Manual mode (M) on the system to arrive at the Dedicated Service Tools (DST). Then, in DST, set the console mode system value to Operations Console, and continue the IPL to sign on.

To set the system to manual mode, do the following:

vFor systems without logical partitions, see the Changing operating modes and IPL types topic in the Information Center under System hardware -> Restarting the system (IPL) -> IPL type.

vFor systems with logical partitions, see the Changing operating mode for a logical partition topic in the Information Center under Systems

Management -> Logical partitions -> Managing logical partitions -> Restarting and powering down a system with logical partitions.

28iSeries 940x RISC-to-RISC Road Map V5R1

Page 40
Image 40
IBM SA41-5155-05 manual Performing a new system backup, Perform a normal IPL