vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Lit light path

 

 

 

diagnostics LED with

 

 

 

the system-error or

 

 

 

information LED also

 

 

 

lit

Description

Action

 

 

 

 

SERVICE

There is a fault in the Remote

1. Reseat the Remote Supervisor Adapter II SlimLine.

PROCESSOR BUS

Supervisor Adapter II SlimLine.

2. Update the firmware for the Remote Supervisor

 

 

 

 

 

Adapter II SlimLine (see the Problem

 

 

 

Determination and Service Guide on the IBM

 

 

 

System x Documentation CD).

 

 

3. Replace the Remote Supervisor Adapter II

 

 

 

SlimLine.

 

 

 

 

MEMORY

Memory failure.

1. Remove the DIMM that has the lit error LED; then,

 

Note: The error LED on the DIMM

 

 

press the light path diagnostics button on the

 

is also lit.

 

 

 

DIMM to identify the failed DIMM.

 

 

 

 

 

2.

Reseat the DIMM.

 

 

3. Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System board

 

 

 

 

DASD/RAID

A hard disk drive, integrated SAS

1. Reinstall the removed drive.

 

controller, or integrated RAID error

 

2. Reseat the following components:

 

has occurred.

 

 

a. Failing hard disk drive

 

Notes:

 

 

 

b. SAS hard disk drive backplane

 

1. The error LED on the failing

 

 

 

c. SAS signal and power cables

 

hard disk drive is also lit.

 

 

 

d. ServeRAID-8k adapter

 

2. Check the BMC event log for a

 

 

3.

Replace the following components one at a time,

 

ServeRAID-8k or RAID error.

 

 

 

in the order shown, restarting the server each time:

 

 

 

a. Failing hard disk drive

 

 

 

b. SAS hard disk drive backplane

 

 

 

c. SAS signal and power cables

 

 

 

d. ServeRAID-8k adapter

 

 

 

e. (Trained service technician only) System board

 

 

 

 

FAN

A fan has failed or has been

1. Reinstall the removed fan.

 

removed.

 

2.

Reseat the fan.

 

Note: A failing fan can also cause

 

3.

If an individual fan LED is lit, replace the fan.

 

the TEMP LED to be lit.

 

 

4. (Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

Chapter 5. Solving problems 93

Page 107
Image 107
IBM Type 7977 manual Service