vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action |
|
|
|
175 | Service processor flash code damaged or | 1. Update the Remote Supervisor Adapter II |
| not installed. | |
| firmware (see the Problem Determination and | |
| Note: In this case, the service processor is | |
| Service Guide on the IBM System x | |
| the optional Remote Supervisor Adapter II | |
| Documentation CD). | |
| SlimLine. | |
| 2. Replace the Remote Supervisor Adapter II | |
|
| |
|
| SlimLine. |
|
|
|
184 | 1. Run the Configuration/Setup Utility program, | |
|
| |
|
| select Load Default Settings, and save the |
|
| settings. |
|
| 2. Clear CMOS memory. See the Problem |
|
| Determination and Service Guide on the IBM |
|
| System x Documentation CD for information |
|
| about how to clear CMOS memory. |
|
| 3. Reseat the battery. |
|
| 4. Replace the following components, one at a time, |
|
| in the order shown, restarting the server each |
|
| time: |
|
| a. Battery |
|
| b. (Trained service technician only) System |
|
| board |
|
|
|
187 | VPD serial number not set. | 1. Set the serial number by updating the BIOS code |
|
| |
|
| level (see the Problem Determination and Service |
|
| Guide on the IBM System x Documentation CD). |
|
| 2. Reseat the Remote Supervisor Adapter II |
|
| SlimLine. |
|
| 3. Replace the following components, one at a time, |
|
| in the order shown, restarting the server each |
|
| time: |
|
| a. Remote Supervisor Adapter II SlimLine |
|
| b. (Trained service technician only) System |
|
| board |
|
|
|
188 | Remote Supervisor Adapter II SlimLine | Replace the Remote Supervisor Adapter II SlimLine. |
| EEPROM error |
|
|
|
|
189 | An attempt was made to access the server | Restart the server and enter the administrator |
| with an incorrect password. | password; then, run the Configuration/Setup Utility |
|
| program and change the |
|
| Note: If you forgot the |
|
| administrator password, you can change the position |
|
| of the jumper on pin 2 on SW4 to the ON position to |
|
| bypass the password check. This enables you to |
|
| reset the passwords. |
|
|
|
196 | Microprocessors do not have the same L2 | Install microprocessors with the same L2 or L3 cache |
| or L3 cache size. | size. |
|
| Note: Do not mix |
|
| processors in the same system. |
|
|
|