Error code

Description

Action

 

 

 

 

 

 

161

Real-time clock battery error.

1.

Reseat the battery.

 

 

 

 

2.

Clear CMOS memory. See the Problem

 

 

 

Determination and Service Guide on the IBM

 

 

 

System x Documentation CD for information

 

 

 

about how to clear CMOS memory.

 

 

3.

Replace the following components, one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

162

A device configuration has changed

1.

Run the Configuration/Setup Utility program,

 

 

 

 

 

select Load Default Settings, and save the

 

 

 

settings.

 

 

2.

Clear CMOS memory. See the Problem

 

 

 

Determination and Service Guide on the IBM

 

 

 

System x Documentation CD for information

 

 

 

about how to clear CMOS memory.

 

 

3.

Reseat the following components:

 

 

 

a.

Battery

 

 

 

b.

Failing device

 

 

4.

Replace the following components, one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b.

Failing device

 

 

 

c. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

163

Real-time clock error.

1.

Run the Configuration/Setup Utility program,

 

 

 

 

 

select Load Default Settings, make sure that the

 

 

 

date and time are correct, and save the settings.

 

 

2.

Clear CMOS memory. See the Problem

 

 

 

Determination and Service Guide on the IBM

 

 

 

System x Documentation CD for information

 

 

 

about how to clear CMOS memory.

 

 

3.

Reseat the battery.

 

 

4.

Replace the following components, one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Battery

 

 

 

b. (Trained service technician only) System

 

 

 

 

board

 

 

 

 

 

Chapter 5. Solving problems 65