vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action | |
|
|
|
|
1810 | PCI error. | 1. | Make sure that no devices have been disabled in |
|
| ||
|
|
| the Configuration/Setup Utility program. |
|
| 2. | Reseat the failing adapter. |
|
|
| Note: If an error LED is lit for a specific adapter, |
|
|
| reseat that adapter first; if no LEDs are lit, reseat |
|
|
| each adapter one at a time, restarting the server |
|
|
| each time, to isolate the failing adapter. |
|
| 3. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. Each adapter |
|
|
| b. (Trained service technician only) |
|
|
|
|
01295085 | ECC checking hardware test error. | 1. | Reseat the following components: |
|
| ||
|
|
| a. DIMM |
|
|
| b. (Trained service technician only) |
|
|
| Microprocessor |
|
| 2. | Replace the following components one at a time, |
|
|
| in the order shown, restarting the server each |
|
|
| time: |
|
|
| a. (Trained service technician only) |
|
|
| Microprocessor |
|
|
| b. DIMM |
|
|
| c. (Trained service technician only) System |
|
|
| board |
|
|
|
|
01298001 | No update data for processor 1. | 1. | Make sure that all microprocessors have the |
|
| ||
|
|
| same cache size (see the Problem Determination |
|
|
| and Service Guide on the IBM System x |
|
|
| Documentation CD). |
|
| 2. | Update the BIOS code. |
|
| 3. | (Trained service technician only) Reseat |
|
|
| microprocessor 1. |
|
| 4. | (Trained service technician only) Replace |
|
|
| microprocessor 1. |
|
|
|
|
01298002 | No update data for processor 2. | 1. | Make sure that all microprocessors have the |
|
| ||
|
|
| same cache size (see the Problem Determination |
|
|
| and Service Guide on the IBM System x |
|
|
| Documentation CD). |
|
| 2. | Update the BIOS code again (see the Problem |
|
|
| Determination and Service Guide on the IBM |
|
|
| System x Documentation CD). |
|
| 3. | (Trained service technician only) Reseat |
|
|
| microprocessor 2. |
|
| 4. | (Trained service technician only) Replace |
|
|
| microprocessor 2. |
|
|
|
|