vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.
Error code | Description | Action |
| |
|
|
|
| |
1962 | A drive does not contain a valid boot sector. | 1. | Make sure that a bootable operating system is | |
|
|
| installed. | |
|
| 2. | Run the hard disk drive diagnostic tests. | |
|
| 3. | Reseat the following components: | |
|
|
| a. | SAS drive |
|
|
| b. SAS hard disk drive backplane cable | |
|
| 4. | Replace the following components, one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | SAS drive |
|
|
| b. SAS hard disk drive backplane | |
|
|
| c. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
5962 | IDE DVD drive configuration error. | 1. | Run the Configuration/Setup Utility program and | |
|
| |||
|
|
| load the default settings (see the Problem | |
|
|
| Determination and Service Guide on the IBM | |
|
|
| System x Documentation CD). | |
|
| 2. | Reseat the following components: | |
|
|
| a. | DVD drive cable |
|
|
| b. | DVD drive |
|
| 3. | Replace the following components, one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | DVD drive cable |
|
|
| b. | DVD drive |
|
|
| c. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
8603 | 1. | Reseat the pointing device. | ||
|
| |||
|
| 2. | Replace the following components, one at a time, | |
|
|
| in the order shown, restarting the server each | |
|
|
| time: | |
|
|
| a. | Pointing device |
|
|
| b. (Trained service technician only) System | |
|
|
|
| board |
|
|
|
|
|
0001295 | ECC circuit check. | 1. | Reseat DIMMs | |
|
| |||
|
| 2. | Replace the DIMMs, one at a time, restarting the | |
|
|
| server each time. | |
|
|
|
|
|
Chapter 5. Solving problems 69