vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

 

Testing the monitor

1.

Make sure that the monitor cables are firmly connected.

 

 

2.

Try using a different monitor on the server, or try using the monitor that is being

 

 

tested on a different server.

 

3.

Run the diagnostic programs. If the monitor passes the diagnostic programs,

 

 

the problem might be a video device driver.

 

4.

Reseat the Remote Supervisor Adapter II SlimLine.

 

5.

Replace the following components one at a time, in the order shown, restarting

 

 

the server each time:

 

 

a. Remote Supervisor Adapter II SlimLine

 

 

b. (Trained service technician only) System board

 

 

 

The screen is blank.

1.

If the server is attached to a KVM switch, bypass the KVM switch to eliminate it

 

 

 

as a possible cause of the problem: connect the monitor cable directly to the

 

 

correct connector on the rear of the server.

 

2.

Make sure that:

 

 

v The server is turned on. If there is no power to the server, see “Power

 

 

problems” on page 86.

 

 

v The monitor cables are connected correctly.

 

 

v The monitor is turned on and the brightness and contrast controls are

 

 

adjusted correctly.

 

 

v No beep codes sound when the server is turned on.

 

 

Important: In some memory configurations, the 3-3-3 beep code might sound

 

 

during POST, followed by a blank monitor screen. If this occurs and the Boot

 

 

Fail Count option in the Start Options of the Configuration/Setup Utility

 

 

program is enabled, you must restart the server three times to reset the

 

 

configuration settings to the default configuration (the memory connector or

 

 

bank of connectors enabled).

 

3.

Make sure that the correct server is controlling the monitor, if applicable.

 

4.

See the Problem Determination and Service Guide on the IBM System x

 

 

Documentation CD.

 

If the problem remains, call for service.

 

 

 

The monitor works when you

1.

Make sure that:

turn on the server, but the

 

v The application program is not setting a display mode that is higher than the

screen goes blank when you

 

 

capability of the monitor.

start some application

 

 

v You installed the necessary device drivers for the application.

programs.

 

 

2.

Run video diagnostics (see the Problem Determination and Service Guide on

 

 

the IBM System x Documentation CD).

 

 

v If the server passes the video diagnostics, the video is good; see the

 

 

Problem Determination and Service Guide on the IBM Documentation CD

 

 

that comes with your system.

 

 

v (Trained service technician only) If the server fails the video diagnostics,

 

 

replace the system board.

 

If the problem remains, call for service.

 

 

 

Chapter 5. Solving problems 83