IBM Type 7977 manual Error code, Description, Action

Models: Type 7977

1 124
Download 124 pages 47.5 Kb
Page 87
Image 87
Manual background

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

1804

No more memory (below 1 MB for a PCI

1.

Remove the failing adapter

 

adapter).

 

2.

Reseat each adapter

 

 

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Each adapter

 

 

 

b. (Trained service technician only) PCI-X board

 

 

 

 

 

1805

PCI option ROM checksum error.

1.

Make sure that the settings for the adapter and all

 

 

 

 

 

other adapters in the Configuration/Setup Utility

 

 

 

program are correct.

 

 

2.

If the error code indicates a particular PCI or

 

 

 

PCI-X slot or device, remove that device.

 

 

3.

Reseat each adapter

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Each adapter

 

 

 

b. (Trained service technician only) PCI-X board

 

 

 

 

 

1806

PCI built-in self-test failure.

1.

Make sure that the settings for the adapter and all

 

 

 

 

 

other adapters in the Configuration/Setup Utility

 

 

 

program are correct.

 

 

2.

If the error code indicates a particular PCI or

 

 

 

PCI-X slot or device, remove that device.

 

 

3.

Reseat each adapter

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Each adapter

 

 

 

b. (Trained service technician only) PCI-X board

 

 

 

 

 

1807, 1808

General PCI error.

1.

Make sure that no devices have been disabled in

 

 

 

 

 

the Configuration/Setup Utility program.

 

 

2.

Reseat the failing adapter.

 

 

 

Note: If an error LED is lit for a specific adapter,

 

 

 

reseat that adapter first; if no LEDs are lit, reseat

 

 

 

each adapter one at a time, restarting the server

 

 

 

each time, to isolate the failing adapter.

 

 

3.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a.

Each adapter

 

 

 

b. (Trained service technician only) PCI-X board

 

 

 

 

 

Chapter 5. Solving problems 73

Page 87
Image 87
IBM Type 7977 manual Error code, Description, Action