Icom IC-R3 Skip channel setting, Scan resume condition, Setting the scan pause time

Models: IC-R3

1 64
Download 64 pages 60.25 Kb
Page 26
Image 26
■Skip channel setting

6 SCAN OPERATION

Skip channel setting

Memory channels can be set to be skipped for memory skip scan. In addition, memory channels can be set to be skipped for both memory skip scan and frequency skip scan. These are useful to speedup the scan interval.

qSelect memory mode with [V/M].

wRotate [DIAL] to select a memory channel to be pro- grammed as a skip channel.

eWhile pushing [FUNC], push [(V/M) SKIP] one or more

times to select a condition.

• No indication

: channel will not be skipped.

• “SKIP” or “ ” appears

: channel skipped during memory

 

scan.

“PSKIP” or “P ” appears : channel skipped during memory scan; frequency skipped during full, band and programmed scans.

■Scan resume condition This setting is effective when the frequency skip function ◊Setting the scan pause time (“PSKIP” or “P ”) is turned ON. See p. 24 for details.

FM

 

 

FM

 

SKIP

FM

 

PSKIP

 

 

M:A00

 

 

M:A00

 

 

M:A00

146.010.000

146.010.000

146.010.000

TS

15.0

TS

15.0

TS

15.0

S1 3 5 7 9

S1 3

5

7 9

S1 3

5

7 9

VOL

 

 

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

FM

FM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

Non-skip channel

Skip channel

Skip channel and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency skip channel

Scan resume condition

Setting the scan pause time

The scan pauses when receiving signals according to the scan pause time. It can be set from 2–20 sec. or unlimited.

qPush [FUNC] + [(MODE) SET] momentarily to enter set mode.

• Select a non-band scope screen in advance for color LCD.

wRotate [DIAL] until “Pause Scan” or “PAUSE” appears.

“PAUSE” disappears after 1 sec. and the previously selected scan pause time and “PA” appears when color LCD is OFF.