Icom IC-R5 Memory clearing, Push V/MS.MW~ for 1 sec. to clear the contents, Essary

Models: IC-R5

1 80
Download 80 pages 54.23 Kb
Page 33
Image 33

Memory clearing

Contents of programmed memories can be cleared (blanked), if desired.

qPush [V/M•S.MW•~] for 1 sec. to select select memory write condition.

1 short and 1 long beeps sound.

” indicator and memory channel number blink.

Do not hold [V/M•S.MW•~] for more than 2 sec. otherwise the memory contents will be copied to VFO.

wRotate [DIAL] to select the desired memory channel to be cleared.

eWhile pushing [MODE•SCAN], rotate [DIAL] to select “CLEAR.”

After releasing [MODE•SCAN], “CLR” is displayed instead of the

frequency indication, and only “ ” indicator blinks.

“CLEAR” item can also be selected by pushing [MODE•SCAN] several times.

MEMORY CHANNELS 5

rPush [V/M•S.MW•~] for 1 sec. to clear the contents.

3 beeps sound.

Return to VFO or memory mode, if VFO is selected before per- forming the step q.

Return to select memory write conditions if memory mode is se-

lected before performing the step q.— “ ” indicator memory 5 and channel number blink. Push [V/M•S.MW•~] momentarily

to return to memory mode.

Push for 1 sec.

While pushing [FUNC], push [V/M•S.MW•~] for 1 sec.

after the step w is operated can also be cleared the mem- ory contents. In this case, the steps e and r are not nec-

[DIAL]

[V/M•S.MW•~]

[MODE•SCAN]

After [MODE•SCAN] released

essary.

NOTE: Be careful!— the contents of cleared memories CANNOT be re-called even in bank channel opera- tion.

22

Page 33
Image 33
Icom IC-R5 Memory clearing, Push V/MS.MW~ for 1 sec. to clear the contents, While pushing FUNC, push V/MS.MW~ for 1 sec