Icom IC-R5 instruction manual Scan resume condition, Scan pause timer, Scan resume timer

Models: IC-R5

1 80
Download 80 pages 54.23 Kb
Page 42
Image 42

6 SCAN OPERATION

Scan resume condition

DScan pause timer

The scan pauses when receiving signals according to the scan pause time. It can be set from 2–20 sec. or unlimited.

qPush [TS•SET] for 1 sec. to enter set mode. wRotate [DIAL] to select “EXPAND” item.

eWhile pushing [FUNC], rotate [DIAL] to turn the expand set mode selection ON.

rRotate [DIAL] to select “PAUSE” item.

tWhile pushing [FUNC], rotate [DIAL] to set the desired scan pausing time from 2–20 sec. (2 sec. steps) and “HOLD.”

“2SEC”–“20SEC”: Scan pauses 2–20 sec. while receiving a sig- nal.

“HOLD” : Scan pauses on a received a signal until it disappears.

yPush [TS•SET] to exit set mode.

USING EXPANDED SET MODE

DScan resume timer

The scan re-starts after a signal disappears according to the resume time. it can be set from 0–5 sec. or unlimited.

qPush [TS•SET] for 1 sec. to enter set mode. wRotate [DIAL] to select “EXPAND” item.

eWhile pushing [FUNC], rotate [DIAL] to turn the expand set mode selection ON.

rRotate [DIAL] to select “RESUME” item.

tWhile pushing [FUNC], rotate [DIAL] to set the desired scan pausing time from 0–5 sec. (1 sec. steps) and “HOLD.”

“0SEC” : Scan restarts immediately after the signal dis- appears.

“1SEC”–“5SEC” : Scan restarts 1–5 sec. after the signal disap- pears.

“HOLD” : Scan restarts by rotating [DIAL] only.

• Pause timer setting

yPush [TS•SET] to exit set mode.

[DIAL]

[DIAL]

• Resume timer setting

[FUNC]

After 1 sec.

[TS•SET]

Setting indication

[FUNC]

After 1 sec.

[TS•SET]

Setting indication

31

Page 42
Image 42