16 INSTALLATION / HANDLING

16 INSTALLATION / HANDLING

60Hz

UP6 30E–HA

UP6 40–HA

COMPRESSOR

 

115

 

125

 

150

 

200

 

115

 

125

 

150

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum operating pressure

 

 

 

125

 

150

 

200

 

115

 

125

 

150

 

200

psig (barg)

 

 

 

(8.5)

 

(10.3)

 

(13.8)

 

(8.0)

 

(8.5)

 

(10.3)

 

(13.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory set reload pressure

 

 

 

115

 

140

 

190

 

105

 

115

 

140

 

190

psig (barg)

 

 

 

(7.9)

 

(9.6)

 

(13.1)

 

(7.2)

 

(7.9)

 

(9.6)

 

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow rate

 

 

 

125

 

112

 

92

 

188

 

185

 

170

 

143

cfm (m3/min)

 

 

 

(3.54)

 

(3.17)

 

(2.61)

 

(5.32)

 

(5.24)

 

(4.81)

 

(4.05)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum airend discharge

 

 

 

 

 

 

 

216_F (102_C)

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient operating

 

 

 

 

 

 

36_F(+2_C ) 122_F(+50_C)

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min. max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor enclosure

 

 

ODP

 

 

TEFC

 

ODP

 

 

TEFC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal power

 

 

 

 

30HP

 

 

 

 

 

40HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

1775 RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame

 

 

324T

 

 

324T

 

326T

 

 

326T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insulation class

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING SYSTEM – Air cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling air flow

 

 

 

3100 ft3/min (87.8m3/min)

 

 

3900 ft3/min (110m3/min)

 

Dryer cooling air flow

 

 

 

 

 

 

 

1200 ft3/min

(34m3/min)

 

 

 

 

 

Maximum P in air ducts

 

 

 

 

0.5 inWg (12.7mmH2O) (not recommended for dryer openings)

 

 

 

Compressed air outlet T

 

 

 

 

 

 

 

15_F (8.3_C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling air outlet T

 

 

 

40_F (22_C)

 

 

 

 

 

42_F (23_C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dryer cooling air outlet T

 

 

 

 

 

 

 

11_F (6_C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residual coolant content

 

 

 

 

 

 

 

3ppm (3 mg/m3)

 

 

 

 

 

Separator vessel capacity

 

 

 

 

 

 

 

3.7 US gallons (14 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coolant capacity

 

 

 

 

 

 

 

5.5 US gallons (21 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound pressure level to

 

 

 

69 dB(A)

 

 

 

 

 

69 dB(A)

 

CAGI–PNEUROP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Non–dryer unit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight – base mount unit

 

 

2326 lbs

 

2436 lbs

 

2384 lbs

 

 

2476 lbs

 

 

 

 

(1055 kg)

 

(1105 kg)

 

(1081 kg)

 

(1123 kg)

 

 

 

 

 

 

 

 

 

 

 

 

Weight – dryer option unit

 

 

2576 lbs

 

2686 lbs

 

2634 lbs

 

 

2726 lbs

 

 

 

 

(1167 kg)

 

(1218 kg)

 

(1194 kg)

 

(1236 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

230/460 Dual voltage machines are fitted with a decal to advise the correct supply voltage as connected from the factory.

Factory units wired for 230V supply can be re–wired to 460V supply voltage by re–wiring the main drive motor and the fan motor as shown on the electrical schematic AND by replacing the fan motor starter CCN 22395800 - 50 HP with CCN 22395792 - 50 HP (shipped loose). The main motor overload and the fan motor starter overload settings should be adjusted accordingly – reference the IEC decal mounted inside the starter door. Also, the transformer primary voltage connections will need to be re–wired for the new supply voltage.

Re–wiring should only be effected by a competent Electrician.

SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE,

http://air.ingersollrand.com

HP50–PE, HXP50–PE

 

Page 18