Switch, high refrigerant pressure (option)

OPERATING INSTRUCTIONS – ELECTRO–PNEUMATIC

25

 

 

LEGEND

1PS

Switch, pressure

1RPS

Switch, high refrigerant pressure (option)

2RPS

Switch, fan pressure (option)

RST

Switch, reset

1SV

Valve, solenoid (load) N.C.

3SV

Valve, solenoid (blowdown) N.O.

5SV

Valve, solenoid (modulation option)

6SV

Valve, solenoid (modulation option)

S1

Switch, selector (modulation option)

SS

Switch, selector Off/On

TDR1

Relay timed delay (10 sec.)

TDR1a

Contact, relay – timed

TDR1b

Contact, relay – instant

TR

Relay, restart, time delay (6 min)

TRa

Contact, relay

VAR Varistor

Barrier terminal strip

NOTES

1.Approved fused disconnect or circuit breaker per N.E.C. requirements must be provided by customer.

2.Dashed lines represent wiring by customer.

3.Sizing of electrical components not supplied by Ingersoll Rand is the responsibility of the customer and should be done in accordance with the information on the compressor data plate N.E.C. and local electrical codes.

4..When changing the supply voltage, ensure that:

a)The motor and the transformer are rewired for the new voltage

b)The motor overload is adjusted to the proper setting.

5.Verify actual motor conditions with motor schematic.

http://air.ingersollrand.com

SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE,

EP50–PE, HP50–PE, HXP50–PE