AIR Compressor Group Bonded Warranty & Registered Start UP
Contents & Abbreviations
Foreword
If in Doubt Consult Supervision
Use of the machine fitted with non Ingersoll Rand approved
Copyright 2008 Ingersoll Rand Company
Decals ISO Symbols
Graphic Form and Meaning of ISO Symbols
Reset
Use fork lift truck from this side only
Power Inspect Clean
Decals
Every X months, if sooner than required by Operating hours
Change / Replace
Decals Ansi Symbols
Graphic Form and Meaning of Ansi Symbols
Specifications, compressor package
Decals Ansi
Hz Units
Ccn Qty
View Back View Front
Breathing AIR Precaution
Safety
Avoid INGESTION, Skin Contact and Inhalation of Fumes
Condensate disposal
General Information
KEY
General Information
Installation / Handling
Unpacking
Before starting machine remove shipping bolt and discard
Location in the Plant
Discharge Piping
Motor
Compressor
General Data
Cooling System Air cooled
Dryer Option Technical Information 60Hz General
Control settings
Performance
Electrical Data ALL Units SSR UP6-40
Standard voltage
Package
ODP Tefc
Power nominal 30HP Full load current at maximum
Electrical Data ALL Units SSR UP6-40-HA
Pressure Full load current at maximum
Electrical Data ALL Units SSR 30E-HA
All data applies to standard product only
Electrical Data
General Operation
Operating Instructions General
Do not direct the airflow at face or eyes
Operating Instructions ELECTRO-PNEUMATIC
NORMAL/EMERGENCY Stopping
Function Test
Full Voltage Wiring Schematic
Switch, pressure
Switch, fan pressure option
Switch, reset
Switch, selector modulation option
Star Delta Wiring Schematic
TDa Relay, delay off contact
Contactor, star
Relay, delta starting 10 sec
TDR1a Contact, relay timed TDR1b Contact, relay instant
Control Piping Diagram
Power OUT Restart Optional
Power OUT Restart Time
Operating Instructions Intellisys Option
Intellisys Control and Instrumentation Prior to Starting
Airend Discharge Temperature L.E.D
Alarm L.E.D
Instrument Panel Function Package Discharge Pressure L.E.D
Sump Pressure L.E.D
Power L.E.D
Airend Temperature
Starter Fault
Temperature Sensor
Control Power Loss
Failed Calibration
Remote Start Failure
Remote Stop Failure
Delay Load Time
Modulation Control
ACS Control Intellisys w/ Modulation Option only
Modulation Only
Fault Analysis
Operation Power Outage Restart Option
Function test
Sensor, temperature dryer air option
Sensor, presure, line/sump
Option, modulation control
1FU, 2FU Fuses, primary voltage
Horn, power outage option
Contacts, remote alarm, option
Switch, remote start option
Switch, remote stop option
Switch, high refrigerant pressure option
7FU, 8FU Module, option
1Ma Contact, aux. main contactor
Supressor
1Sa, b Contact, aux. star contactor
Valve, solenoid blowdown 10.Valve, solenoid load
Period Maintenance
Maintenance
Routine Maintenance
TOP UP Coolant Procedure
Coolant Change Procedure
Coolant Filter Change Procedure
AIR Filter Element Change Procedure
Dryer Maintenance Dryer Option
Separator Cartridges Change Procedure
Cooler Cleaning Procedure
To Adjust the Lower SET Point
To Adjust the Upper SET Point
To Check the Lower SET Point
Http//air.ingersollrand.com
Timer Settings
Troubleshooting Cause Action
Electric Drain Valve Product Description
Operation
Modulate Control Valve Adjustment
Modulation Valve
Trouble Shooting
Problem Cause Remedy
Dryer Option
REV Fecha
Grupo DE Compresores DE Aire Garantia Y Arranque Registrado
Mantenimiento Resolucion DE Averias Abreviaturas Y Simbolos
Contenido & Abreviaturas
Generalidades Electroneumatico Intellisys
SI Tiene Dudas Consulte AL Supervisor
Preambulo
Tabla
Calcomanias Simbolos ISO
Forma Grafica Y Significado DE LOS Simbolos ISO
Utilizar la carretilla elevadora en esta lado
Reposicionar
Energia Electrica Inspeccionar Limpiar
Calcomanias
Cambiar / Montar DE Nuevo
Calcomanias Simbolos Ansi
Forma Grafica Y Significado DE LOS Simbolos Ansi
Calcomanias Ansi
Unidades de 60 Hz
Elemento ccn Cantidad Descripción
Especificaciones, unidad de compresor
Calcomanias Ansi
Seguridad
Advertencia
Eliminación del condensado
Informacion General
Clave
Informacion General
Nota Dimensiones expresadas en mm pulgadas
Instalación / Manejo
Nota
Notas
Desembalaje
Aviso
Ubicacion EN LA Planta
Nota
Precaucion
Refrigerador Refrigeración por aire
Compresor
Datos Generales
115 125 150 200 Presión máxima de trabajo
Presión de recarga fijada en
140 190 Fábrica 13.1
Psig barg Medida del gasto
Ajustes de control
Barg psig Ajuste del interruptor de alta
Presión Barg psig Ajuste del interruptor de
Presión del ventilador Encendido/apagado on/off Barg psig
Datos Electricos Todas LAS Unidades SSR UP6-40
Tensión estándar
Unidad
Datos Electricos FV / Estrella triángulo
Datos Electricos Todas LAS Unidades SSR UP6-40-HA
Datos Electricos Todas LAS Unidades SSR 30E-HA
Potencia nominal 30HP Corriente de plena carga a
Véase la nota Http//air.ingersollrand.com
Caracteristicas Electricas
Funcionamiento General
Instrucciones DE Funcionamiento Generalidades
No dirigir el flujo de aire hacia la cara o hacia los ojos
Instrucciones DE Funcionamiento Electroneumatico
Parada NORMAL/DE Emergencia
Arranque
Prueba DE Funcionamiento
Esquema DE Cableado Plena Tension
Leyenda
Interruptor, presión
Interruptor, presión del ventilador opción
Interruptor, reposición
Válvula, solenoide opción de modulación
Instrucciones DE Funcionamiento Opcion Intellisys
Contactor, triángulo
Contactor, estrella
Relé, arranque triángulo 10 segundos
TDa Relé, contacto fuera retardo
TRa Contacto, relé
Esquema DE Conductos DE Control
Tuberías de 3/8 pulgada Tuberías de 1/4 pulgada
Control Intellisys E Instrumentacion Antes DEL Arranque
Rearranque POR INTERRUPCIÓN/FALLO DE Potencia opcional
Tiempo DE Rearranque POR INTERRUPCIÓN/FALLO DE Potencia
Parada Normal
LED DE Alarma
LED DE Temperatura DE Descarga DEL Airend
LED DE Presión DEL Colector
LED DE Caída DE Presión EN EL Separador
LED DE Presencia DE Tensión
LED DE Rearranque Automático
Modos DE Contrl DE LA Maquina Control DE LA Capacidad
Control EN Linea Fuera DE Linea
Sensor DE Temperatura
Sensor DE Presion
Calibración Fallida
Fallo DE LA Parada Remota
Control DE Modulación
Control ACS Intellisys con Opción DE Modulación
Modulación
Tiempo de retraso de carga
Prueba de la función
Análisis de fallos
Instrucciones DE Funcionamiento Opcion Intellisys
Sensor, temperatura aire secador opción
1FU, 2FU Fusibles, tensión primaria
Opción, control de modulación
Contactos, alarma a distancia, opción
Bocina, fallo de potencia opción
Interruptor, alta presión del refrigerante opción
Interruptor, arranque a distancia opción
Bocinas, fallo de potencia opción
Supresor
1Sa, b Contacto, contactor estrella auxiliar
Válvula, solenoide carga Normalmente cerrada
Esquema DE Conductos DE Control
Período Mantenimiento
Mantenimiento
Mantenimiento DE Rutina
Peligro
Procedimiento Para Restablecer EL Nivel DEL Refrigerante
Procedimiento DE Cambio DEL Refrigerante
Procedimiento DE Cambio DEL Filtro DE Refrigerante
Procedimiento DE Cambio DEL Elemento DEL Filtro
Procedimiento Para Cambiar LOS Cartuchos DEL Separador
Mantenimiento DEL Secador Opcion DE Secador Advertencia
Procedimiento para comprobación del nivel de aceite
Adición de aceite
Para Ajustar EL Punto Fijado Superior
Para Comprobar EL Punto Fijado Inferior
Para Ajustar EL Punto Fijado Inferior
Mantenimiento
Ajustes DEL Temporizador
Funcionamiento
Localizacion DE Fallos
Ajuste DE LA Válvula DE Control DE Modulación
Figura 2 Válvula DE Modulación
Resolucion DE Averias
Averia Causa Remedio
Opcion DE Secador
Bien Notas
Page
REV Date
Garantie
Contenu & Abreviations
Maintenance Recherche DE Défauts Abréviations & Symboles
Generalites ELECTRO-PNEUMATIQUE Intellisys
Utilisation de la machine avec des pièces installées, non
AVANT-PROPOS
EN CAS DE DOUTE, REFEREZ-VOUS a Votre Superviseur
Tableau
Decals Symboles ISO
Structure Graphique ET Signification DES Symboles ISO
Pour le levage avec fourche, n’utiliser que ce Cõté
Recalage
Puissance Controler Nettoyer
Changer / Remplacer
Decals Symboles Ansi
Structure Graphique ET Signification DES Symboles Ansi
Unités de fréquence 60 Hz
Article Nic Quantité Description
Repère, rotation 60Hz
Repère, patte de fixation transit
Autocollant, attention à l’air
Autocollant, flèche indiquant le sens de
Precautions
Precautions Contre L’UTILISATION Pour LA Respiration
Securite
Avertissement
Electricité
Mise au rebut du condensat
Lexique
Informations Générales
Electro vanne 21.Orifice Voyant, restriction d’air
Informations Générales
Installation / Manutention
Nota Les dimensions sont en mm pouces
Desemballage
Elément de Pré filtrage
Remarque
Localisation Dans L’USINE
Precaution
Tuyauterie DE Refoulement
Compresseur
Moteur
Refroidissement Refroidissement à l’air
Donnees Generales
115 125 150 200 Pression maximum
Psig barg Pression de rechargement
Psig barg Débit
112 188 185 170 143 Cfm m3/min Température Maximum
Information Technique SUR L’OPTION Secheur 60Hz Généralités
Chaud Barg psig Réglage du contacteur haute
Pression Barg psig Réglage marche/arrêt du
Contacteur de pression du Ventilateur Barg psig
Caracteristiques Electriques Toutes LES Unites SSR UP6-40
Specifications Electriques FV / Etoile Triangle
Groupe
Puissance nominale 30HP Intensité
Caracteristiques Electriques Toutes LES Unites SSR 30E-HA
Consultez note Http//air.ingersollrand.com
Electricite
Attentio
Generalites
Instructions DE Fonctionnement Generalites
Ne dirigez pas le débit d’air vers le visage/les yeux
Instructions DE Fonctionnement ELECTRO-PNEUMATIQUE
Arret NORMAL/D’URGENCE
Mise EN Marche
Essai DE Fonctionnement
Schema DE Cablage DE Tension Maximum
Contacteur, pression
Contacteur de pression du ventilateur option
Commutateur, réinitialisation
Electrovalve charge N.C. normalement fermée
Schema DE Cablage Etoile Triangle
Contacteur, étoile
Relais, démarrage triangle 10 sec
TDa Relais, contact suppression temporisation
TRa Contact, relais
Schema DES Tuyauteries DE Commande
Instructions DE Fonctionnement Option Intellisys
Redémarrage Après Mise Hors Tension en option
Le cas échéant
Temps DE Redémarrage Après Mise Hors Tension
Lampe LED Alarme
Fonction DU Panneau D’INSTRUMENTS
Lampe LED DE Nombre D’HEURES Total
Lampe LED Modulation
Temperature DU Bloc Compresseur
Temperature Capteur
Lampe LED Sous Tension
Lampe Redemarrage Automatique
Probleme Demarrage a Distance
Probleme Arret a Distance
Sonde DE Pression
Calibration Defectueuse
Commande DE Modulation
Commande de modulation
Code
Délai de chargement
Test de fonctionnement
Analyse des erreurs possibles
Option, commande modulation
Option Poro
Capteur, pression, ligne / carter
Commutateur, arrêt d’urgence
Contacts, alarme à distance, option
Klaxon, panne d’alimentation électrique option
Contacteur, démarrage à distance option
Contacteur, arrêt à distance option
Suppresseur
1Sa, b Contact, contacteur étoile auxiliaire
Electrovalve de ligne / carter
Période Maintenance
Maintenance DE Routine
Procedure D’EMPLISSAGE DU Produit DE Refroidissement
Procedure DE Vidange DU Liquide DE Refroidissement
Procedure DE Changement DU Filtre a Coolant
Attentoin
Procedure DE Changement DE L’ELEMENT Filtrant
Procedure Pour Remplacer LES Cartouches DU Séparateur
Maintenance DU Secheur Option Sécheur
Procedure DE Nettoyage DU Radiateur
Procédure de vérification du niveau d’huile
Reglage DU Point DE Calage Superieur
Verification DU Point DE Calage Inferieur
Reglage DU Point DE Calage Inferieur
Procedure DE Changement DE LA Couroie / Ressort a GAZ
Entretien DU Separateur D’HUMIDITE
Reglage DE LA Minuterie
Fonctionnement
Recherche DE Pannes
Réglage DE LA Valve DE Commande DE Modulation
Valve DE Commande DE Modulation
Defaut Cause Solution
Recherche DE Défauts
Option Sécheur
Page
REV Data
Grupo Compressor DE AR Garantia Formal E Arranque Registado
Garantia
Índice & Abreviaturas
Manutenção Diagnóstico DE Avarias Abreviaturas E Símbolos
Geral
Electropneumáticos Intellisys
SE Tiver Dúvidas Consulte O Encarregado
Introdução
Uso da máquina montada com componentes não aprovados por
Configuração Gráfica E Significado DOS Símbolos ISO
Autocolante Símbolos ISO
Use o emplihador apenas deste lado
Rearme
Tensão Inspeccionar Limpar
Autocolante
Mudar / Substituir
Configuração Gráfica E Significado DOS Símbolos Ansi
Autocolante Símbolos Ansi
Unidades 60 Hz
Autocolantes Ansi
Ccn Qtd Descrição
Qtd
Segurança
Eliminação de condensado
Informação Geral
Chave
Informação Geral
Instalação / Manuseamento
Nota As dimensões são em mm polegadas
Desambalamento
Precaução
Instalação
Tubagem DE Descarga
Sistema DE Arrefecimento Arrefecido a ar
Dados Gerais
Psig barg Pressão de recarga regulada
115 125 150 200 Pressão máxima de
Psig barg Caudal
Informação Técnica Opção COM Secador 60Hz Geral
Regulações de controlo
Conjunto
Dados Eléctricos Todas AS Unidades SSR UP6-40
Dados ELÉCTRICOS-voltagem total/ Estrela Triângulo
Dados Eléctricos Todas AS Unidades SSR 30E-HA
Dados Eléctricos Todas AS Unidades SSR UP6-40-HA
Potência nominal 30HP Corrente a carga máxima à
Dados Eléctricos
Funcionamento Geral
Instruções DE Funcionamento Geral
Não aponte o fluxo de ar à face ou aos olhos
Instruções DE Funcionamento Electropneumática
Paragem NORMAL/EMERGÊNCIA
Carregue no botão Reset Rearmar 8. O indicador de avaria
Teste DE Função
Http//air.ingersollrand.com
Esquema Eléctrico DE Voltagem Total
Pressóstato
Interruptor, pressão de refrigerante alta opção
Interruptor, rearmar
Cliente
Esquema Eléctrico Estrela Triângulo
Interruptor, pressão ventoinha opção
Contactor, estrela
Electroválvula opção modelação
Relé, arranque estrela 10 segundos
Diagrama DA Tubagem DE Controlo
Instruções DE Funcionamento Opção Intellisys
Controlo Intellisys E Instrumentos Antes do Arranque
Rearranque POR Falta DE Energia opcional
Tempo DE Rearranque POR Falta DE Energia
10 L.E.D. Sinalizador DE Alarme
E.D. Horas Totais
E.D. Horas EM Carga
E.D. Sinalizador DE CARGA/VAZIO
Sinalizador DE Tensão
Sinalizador DE Rearranque Automático
Modos DE Controlo DA Máquina Controlo DE Capacidade
Controlo Carga Vazio
Sensor DE Pressão
Falha DE Calibração
Perda DA Tensão DE Comando
Falha no Arranque Remoto
Controlo DE Modulação
Código
Controlo ACS Intellisys c/ Opção DE Modulação Apenas
Controlo de Modulação
Teste de funcionamento
Operação Opção DE Rearranque Após Falha DE Corrente
Análise de Avarias
Sensor, pressão, linha/reservatório
Sensor, temperatura, descarga airend
Sensor, temperatura ar secador opção
1FU, 2FU Fusíveis, voltagem principal
Contactos, alarme remoto, opção
Buzina, interrupção de corrente opção
Interruptor, arranque remotoopção
Interruptor, paragem remotaopção
Módulo, opção
1Sa, b Contacto, contactor estrela auxiliar
Electroválvula linha / reservatório
Período Manutenção
Manutenção
Conservação DE Rotina
Procedimento Para a Mudança DE Refrigerante
Procedimento Para Atestar O Refrigerante
Procedimento Para Mudança do Filtro DE Refrigerante
Procedimento Para Substituição do Elemento do Filtro DE AR
Procedimento Para Substituição DOS Cartuchos do Separador
Manutenção do Secador Opção Secador Advertência
Procedimento para verificação do nível de óleo
Atestamento com óleo
Para Afinar O Ponto DE Regulação Superior
Para Verificar O Ponto DE Regulação Inferior
Para Afinar O Ponto DE Regulação Inferior
Procedimento Para Substituição DE Correia / Tensor DE GÁS
Manutenção do Separador DE Humidade
Solução DE Problemas Causa Acção
Electroválvula DE Drenagem Descrição do Produto
Operação
Regulações do Temporizador
Ajuste DA Válvula DE Controlo DA Modulação
Figura 2 Válvula DE Modulação
Diagn Óstico DE Avarias
Avaria Causa Solução
Diagnóstico DE Avarias
Opção Secador