42 MAINTENANCE

SEPARATOR CARTRIDGES CHANGE PROCEDURE

1.Stop the machine, electrically isolate and vent all trapped pressure.

2.Loosen separator cartridges with the correct tool.

3.Remove the cartridges from the housing; place in a sealed bag and dispose of safely.

4.Clean the mating faces of the housing.

5.Remove the new Ingersoll Rand replacement cartridges from protective package.

6.Apply a small amount of lubricant to the cartridge seal.

7.Screw the new cartridges down until the seal makes contact with the housing, then hand tighten a further half turn.

8.Start the compressor and check for leaks.

CAUTION

This unit is not designed or intended to operate when contaminated with silicone. Lubricants, greases or other items containing silicone should not be used on this unit.

DRYER MAINTENANCE (DRYER OPTION)

WARNING

The dryer’s refrigeration system operates in a pressurised shutdown mode. If the compressor stops, the system will contain high pressure refrigerant. The refrigeration system must only be opened by a qualified technician certified in handling refrigerants. Never adjust thermal expansion valve. It has been factory set.

SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE, HP50–PE, HXP50–PE

Oil level checking procedure

The oil level should be checked regularly. An oil level sight glass is located at the bottom of the refrigeration compressor and while the machine is running on load, oil should always be visible in the sight glass. The normal position is half way.

Adding oil

The refrigeration circuit is hermetically sealed so adding oil should never be necessary unless the system is leaking or has been pumped down or recharged.

If adding oil is necessary, do the following.

Run the dryer for a minimum of 2 minutes, the oil level should be

visible in the sight glass. If not, slowly add the proper oil, using the

appropriate pump, to the Schradert valve on the suction connector of the compressor. Continue until the oil level is visible in the sight glass with the compressor running.

CAUTION

Do not mix oil types. Use only oil specified by IR

COOLER CLEANING PROCEDURE

1.Stop the machine, electrically isolate and vent all trapped pressure.

2.Remove the top cover to obtain access to the cooler.

3.Clean the cooler.

4.Rebuild in reverse order.

http://air.ingersollrand.com

Page 44
Image 44
Ingersoll-Rand SSR UP6 50PEI HF50-PE, SSR UP6 40 Separator Cartridges Change Procedure, Dryer Maintenance Dryer Option

HP50-PE, SSR UP6 50PEI HF50-PE, SSR UP6 50PE, SSR UP6 40, EP50-PE specifications

Ingersoll-Rand is renowned for its premium industrial solutions, and their EP50-PE, SSR UP6 40, HXP50-PE, SSR UP6 50PE, SSR UP6 50PEI, and HF50-PE air compressors are standout products in their lineup. Each model is designed to meet diverse industrial requirements, providing reliable and efficient compressed air solutions.

The EP50-PE model features an energy-efficient design aimed at reducing operational costs while maintaining high performance levels. Its advanced rotary screw technology enhances efficiency and reduces maintenance requirements, allowing for continuous operation. The EP50-PE also incorporates advanced noise reduction features, making it suitable for noise-sensitive environments.

Next in line, the SSR UP6 40 presents an ideal solution for medium to large-scale applications. This rotary screw compressor prioritizes energy efficiency, delivering a reliable flow of compressed air while minimizing energy consumption. Equipped with a variable speed drive, the SSR UP6 40 can adapt to changing demands, ensuring optimal performance. Its durable construction ensures longevity, making it an investment worth considering for any business.

The HXP50-PE further complements Ingersoll-Rand's offerings by providing a robust, high-performance solution designed for demanding applications. This model utilizes cutting-edge technology to deliver consistently high air reliability and quality. A built-in air dryer option can further enhance the system's efficiency by ensuring dry air output, crucial for sensitive operations.

Then there's the SSR UP6 50PE, which stands out with its compact design that doesn't compromise on power or efficiency. It features advanced control options that facilitate easy monitoring and operation, ensuring that users can optimize their air system efficiently. Designed for seamless installation, this model is suitable for various applications across multiple industries.

The SSR UP6 50PEI variant incorporates integrated intelligent controls that allow for real-time diagnostics and monitoring. This feature not only optimizes performance but also aids in preventive maintenance, significantly extending the compressor's life and reliability.

Finally, the HF50-PE model is designed with a focus on high-flow applications. It provides a substantial volume of compressed air, making it ideal for heavy-duty industrial use. Its efficient design enhances airflow, leading to reduced energy consumption while still delivering the needed performance.

Ingersoll-Rand's range of air compressors is marked by a commitment to innovation, efficiency, and reliability. Each model showcases advanced technologies tailored to meet the evolving needs of modern industries, making them a smart choice for businesses seeking quality compressed air solutions.