REV Date October
AIR Compressor Group Bonded Warranty & Registered Start UP
Contents & Abbreviations
Use of the machine fitted with non Ingersoll Rand approved
Foreword
If in Doubt Consult Supervision
Copyright 2008 Ingersoll Rand Company
Reset
Decals ISO Symbols
Graphic Form and Meaning of ISO Symbols
Use fork lift truck from this side only
Every X months, if sooner than required by Operating hours
Power Inspect Clean
Decals
Change / Replace
Decals Ansi Symbols
Graphic Form and Meaning of Ansi Symbols
Hz Units
Specifications, compressor package
Decals Ansi
Ccn Qty
View Back View Front
Avoid INGESTION, Skin Contact and Inhalation of Fumes
Safety
Breathing AIR Precaution
Condensate disposal
General Information
KEY
General Information
Installation / Handling
Unpacking
Discharge Piping
Location in the Plant
Before starting machine remove shipping bolt and discard
General Data
Compressor
Motor
Cooling System Air cooled
Performance
Control settings
Dryer Option Technical Information 60Hz General
Package
Electrical Data ALL Units SSR UP6-40
Standard voltage
ODP Tefc
Pressure Full load current at maximum
Power nominal 30HP Full load current at maximum
Electrical Data ALL Units SSR UP6-40-HA
Electrical Data ALL Units SSR 30E-HA
All data applies to standard product only
Electrical Data
Do not direct the airflow at face or eyes
Operating Instructions General
General Operation
Operating Instructions ELECTRO-PNEUMATIC
NORMAL/EMERGENCY Stopping
Function Test
Full Voltage Wiring Schematic
Switch, reset
Switch, pressure
Switch, fan pressure option
Switch, selector modulation option
Star Delta Wiring Schematic
Relay, delta starting 10 sec
TDa Relay, delay off contact
Contactor, star
TDR1a Contact, relay timed TDR1b Contact, relay instant
Control Piping Diagram
Operating Instructions Intellisys Option
Power OUT Restart Optional
Power OUT Restart Time
Intellisys Control and Instrumentation Prior to Starting
Instrument Panel Function Package Discharge Pressure L.E.D
Airend Discharge Temperature L.E.D
Alarm L.E.D
Sump Pressure L.E.D
Starter Fault
Power L.E.D
Airend Temperature
Temperature Sensor
Remote Start Failure
Control Power Loss
Failed Calibration
Remote Stop Failure
ACS Control Intellisys w/ Modulation Option only
Delay Load Time
Modulation Control
Modulation Only
Function test
Operation Power Outage Restart Option
Fault Analysis
Option, modulation control
Sensor, temperature dryer air option
Sensor, presure, line/sump
1FU, 2FU Fuses, primary voltage
Switch, remote start option
Horn, power outage option
Contacts, remote alarm, option
Switch, remote stop option
1Ma Contact, aux. main contactor
Switch, high refrigerant pressure option
7FU, 8FU Module, option
Supressor
1Sa, b Contact, aux. star contactor
Valve, solenoid blowdown 10.Valve, solenoid load
Routine Maintenance
Maintenance
Period Maintenance
Coolant Filter Change Procedure
TOP UP Coolant Procedure
Coolant Change Procedure
AIR Filter Element Change Procedure
Cooler Cleaning Procedure
Separator Cartridges Change Procedure
Dryer Maintenance Dryer Option
To Check the Lower SET Point
To Adjust the Upper SET Point
To Adjust the Lower SET Point
Http//air.ingersollrand.com
Electric Drain Valve Product Description
Timer Settings
Troubleshooting Cause Action
Operation
Modulate Control Valve Adjustment
Modulation Valve
Trouble Shooting
Problem Cause Remedy
Dryer Option
REV Fecha
Grupo DE Compresores DE Aire Garantia Y Arranque Registrado
Generalidades Electroneumatico Intellisys
Contenido & Abreviaturas
Mantenimiento Resolucion DE Averias Abreviaturas Y Simbolos
Tabla
Preambulo
SI Tiene Dudas Consulte AL Supervisor
Utilizar la carretilla elevadora en esta lado
Calcomanias Simbolos ISO
Forma Grafica Y Significado DE LOS Simbolos ISO
Reposicionar
Cambiar / Montar DE Nuevo
Calcomanias
Energia Electrica Inspeccionar Limpiar
Calcomanias Simbolos Ansi
Forma Grafica Y Significado DE LOS Simbolos Ansi
Elemento ccn Cantidad Descripción
Calcomanias Ansi
Unidades de 60 Hz
Especificaciones, unidad de compresor
Calcomanias Ansi
Seguridad
Advertencia
Eliminación del condensado
Informacion General
Clave
Informacion General
Nota Dimensiones expresadas en mm pulgadas
Instalación / Manejo
Desembalaje
Notas
Nota
Nota
Aviso
Ubicacion EN LA Planta
Precaucion
Datos Generales
Compresor
Refrigerador Refrigeración por aire
140 190 Fábrica 13.1
115 125 150 200 Presión máxima de trabajo
Presión de recarga fijada en
Psig barg Medida del gasto
Presión Barg psig Ajuste del interruptor de
Ajustes de control
Barg psig Ajuste del interruptor de alta
Presión del ventilador Encendido/apagado on/off Barg psig
Unidad
Datos Electricos Todas LAS Unidades SSR UP6-40
Tensión estándar
Datos Electricos FV / Estrella triángulo
Potencia nominal 30HP Corriente de plena carga a
Datos Electricos Todas LAS Unidades SSR UP6-40-HA
Datos Electricos Todas LAS Unidades SSR 30E-HA
Véase la nota Http//air.ingersollrand.com
Caracteristicas Electricas
No dirigir el flujo de aire hacia la cara o hacia los ojos
Instrucciones DE Funcionamiento Generalidades
Funcionamiento General
Instrucciones DE Funcionamiento Electroneumatico
Prueba DE Funcionamiento
Arranque
Parada NORMAL/DE Emergencia
Esquema DE Cableado Plena Tension
Leyenda
Interruptor, reposición
Interruptor, presión
Interruptor, presión del ventilador opción
Válvula, solenoide opción de modulación
Instrucciones DE Funcionamiento Opcion Intellisys
Contactor, triángulo
TDa Relé, contacto fuera retardo
Contactor, estrella
Relé, arranque triángulo 10 segundos
TRa Contacto, relé
Esquema DE Conductos DE Control
Tuberías de 3/8 pulgada Tuberías de 1/4 pulgada
Tiempo DE Rearranque POR INTERRUPCIÓN/FALLO DE Potencia
Control Intellisys E Instrumentacion Antes DEL Arranque
Rearranque POR INTERRUPCIÓN/FALLO DE Potencia opcional
Parada Normal
LED DE Presión DEL Colector
LED DE Alarma
LED DE Temperatura DE Descarga DEL Airend
LED DE Caída DE Presión EN EL Separador
Modos DE Contrl DE LA Maquina Control DE LA Capacidad
LED DE Presencia DE Tensión
LED DE Rearranque Automático
Control EN Linea Fuera DE Linea
Calibración Fallida
Sensor DE Temperatura
Sensor DE Presion
Fallo DE LA Parada Remota
Modulación
Control DE Modulación
Control ACS Intellisys con Opción DE Modulación
Tiempo de retraso de carga
Prueba de la función
Análisis de fallos
1FU, 2FU Fusibles, tensión primaria
Instrucciones DE Funcionamiento Opcion Intellisys
Sensor, temperatura aire secador opción
Opción, control de modulación
Interruptor, alta presión del refrigerante opción
Contactos, alarma a distancia, opción
Bocina, fallo de potencia opción
Interruptor, arranque a distancia opción
Bocinas, fallo de potencia opción
Supresor
1Sa, b Contacto, contactor estrella auxiliar
Válvula, solenoide carga Normalmente cerrada
Esquema DE Conductos DE Control
Mantenimiento DE Rutina
Mantenimiento
Período Mantenimiento
Procedimiento DE Cambio DEL Refrigerante
Peligro
Procedimiento Para Restablecer EL Nivel DEL Refrigerante
Procedimiento DE Cambio DEL Filtro DE Refrigerante
Procedimiento DE Cambio DEL Elemento DEL Filtro
Procedimiento para comprobación del nivel de aceite
Procedimiento Para Cambiar LOS Cartuchos DEL Separador
Mantenimiento DEL Secador Opcion DE Secador Advertencia
Adición de aceite
Para Ajustar EL Punto Fijado Inferior
Para Comprobar EL Punto Fijado Inferior
Para Ajustar EL Punto Fijado Superior
Mantenimiento
Localizacion DE Fallos
Funcionamiento
Ajustes DEL Temporizador
Ajuste DE LA Válvula DE Control DE Modulación
Figura 2 Válvula DE Modulación
Resolucion DE Averias
Averia Causa Remedio
Opcion DE Secador
Bien Notas
Page
REV Date
Garantie
Generalites ELECTRO-PNEUMATIQUE Intellisys
Maintenance Recherche DE Défauts Abréviations & Symboles
Contenu & Abreviations
EN CAS DE DOUTE, REFEREZ-VOUS a Votre Superviseur
Utilisation de la machine avec des pièces installées, non
AVANT-PROPOS
Tableau
Pour le levage avec fourche, n’utiliser que ce Cõté
Decals Symboles ISO
Structure Graphique ET Signification DES Symboles ISO
Recalage
Puissance Controler Nettoyer
Changer / Remplacer
Decals Symboles Ansi
Structure Graphique ET Signification DES Symboles Ansi
Unités de fréquence 60 Hz
Article Nic Quantité Description
Autocollant, attention à l’air
Repère, rotation 60Hz
Repère, patte de fixation transit
Autocollant, flèche indiquant le sens de
Securite
Precautions
Precautions Contre L’UTILISATION Pour LA Respiration
Avertissement
Electricité
Mise au rebut du condensat
Electro vanne 21.Orifice Voyant, restriction d’air
Informations Générales
Lexique
Informations Générales
Installation / Manutention
Nota Les dimensions sont en mm pouces
Remarque
Elément de Pré filtrage
Desemballage
Tuyauterie DE Refoulement
Precaution
Localisation Dans L’USINE
Refroidissement Refroidissement à l’air
Compresseur
Moteur
Donnees Generales
Psig barg Débit
115 125 150 200 Pression maximum
Psig barg Pression de rechargement
112 188 185 170 143 Cfm m3/min Température Maximum
Pression Barg psig Réglage marche/arrêt du
Information Technique SUR L’OPTION Secheur 60Hz Généralités
Chaud Barg psig Réglage du contacteur haute
Contacteur de pression du Ventilateur Barg psig
Groupe
Specifications Electriques FV / Etoile Triangle
Caracteristiques Electriques Toutes LES Unites SSR UP6-40
Consultez note Http//air.ingersollrand.com
Caracteristiques Electriques Toutes LES Unites SSR 30E-HA
Puissance nominale 30HP Intensité
Electricite
Attentio
Ne dirigez pas le débit d’air vers le visage/les yeux
Instructions DE Fonctionnement Generalites
Generalites
Instructions DE Fonctionnement ELECTRO-PNEUMATIQUE
Essai DE Fonctionnement
Mise EN Marche
Arret NORMAL/D’URGENCE
Schema DE Cablage DE Tension Maximum
Commutateur, réinitialisation
Contacteur, pression
Contacteur de pression du ventilateur option
Electrovalve charge N.C. normalement fermée
Schema DE Cablage Etoile Triangle
TDa Relais, contact suppression temporisation
Contacteur, étoile
Relais, démarrage triangle 10 sec
TRa Contact, relais
Schema DES Tuyauteries DE Commande
Le cas échéant
Instructions DE Fonctionnement Option Intellisys
Redémarrage Après Mise Hors Tension en option
Temps DE Redémarrage Après Mise Hors Tension
Lampe LED DE Nombre D’HEURES Total
Lampe LED Alarme
Fonction DU Panneau D’INSTRUMENTS
Lampe LED Modulation
Lampe LED Sous Tension
Temperature DU Bloc Compresseur
Temperature Capteur
Lampe Redemarrage Automatique
Sonde DE Pression
Probleme Demarrage a Distance
Probleme Arret a Distance
Calibration Defectueuse
Code
Commande DE Modulation
Commande de modulation
Délai de chargement
Test de fonctionnement
Analyse des erreurs possibles
Capteur, pression, ligne / carter
Option, commande modulation
Option Poro
Commutateur, arrêt d’urgence
Contacteur, démarrage à distance option
Contacts, alarme à distance, option
Klaxon, panne d’alimentation électrique option
Contacteur, arrêt à distance option
Suppresseur
1Sa, b Contact, contacteur étoile auxiliaire
Electrovalve de ligne / carter
Période Maintenance
Maintenance DE Routine
Procedure DE Changement DU Filtre a Coolant
Procedure D’EMPLISSAGE DU Produit DE Refroidissement
Procedure DE Vidange DU Liquide DE Refroidissement
Attentoin
Procedure DE Changement DE L’ELEMENT Filtrant
Procedure DE Nettoyage DU Radiateur
Procedure Pour Remplacer LES Cartouches DU Séparateur
Maintenance DU Secheur Option Sécheur
Procédure de vérification du niveau d’huile
Reglage DU Point DE Calage Inferieur
Verification DU Point DE Calage Inferieur
Reglage DU Point DE Calage Superieur
Procedure DE Changement DE LA Couroie / Ressort a GAZ
Entretien DU Separateur D’HUMIDITE
Recherche DE Pannes
Fonctionnement
Reglage DE LA Minuterie
Réglage DE LA Valve DE Commande DE Modulation
Valve DE Commande DE Modulation
Defaut Cause Solution
Recherche DE Défauts
Option Sécheur
Page
REV Data
Grupo Compressor DE AR Garantia Formal E Arranque Registado
Garantia
Geral
Índice & Abreviaturas
Manutenção Diagnóstico DE Avarias Abreviaturas E Símbolos
Electropneumáticos Intellisys
Uso da máquina montada com componentes não aprovados por
Introdução
SE Tiver Dúvidas Consulte O Encarregado
Use o emplihador apenas deste lado
Configuração Gráfica E Significado DOS Símbolos ISO
Autocolante Símbolos ISO
Rearme
Mudar / Substituir
Autocolante
Tensão Inspeccionar Limpar
Configuração Gráfica E Significado DOS Símbolos Ansi
Autocolante Símbolos Ansi
Ccn Qtd Descrição
Autocolantes Ansi
Unidades 60 Hz
Qtd
Segurança
Eliminação de condensado
Informação Geral
Chave
Informação Geral
Instalação / Manuseamento
Nota As dimensões são em mm polegadas
Desambalamento
Tubagem DE Descarga
Instalação
Precaução
Sistema DE Arrefecimento Arrefecido a ar
Dados Gerais
Psig barg Caudal
115 125 150 200 Pressão máxima de
Psig barg Pressão de recarga regulada
Informação Técnica Opção COM Secador 60Hz Geral
Regulações de controlo
Dados ELÉCTRICOS-voltagem total/ Estrela Triângulo
Dados Eléctricos Todas AS Unidades SSR UP6-40
Conjunto
Potência nominal 30HP Corrente a carga máxima à
Dados Eléctricos Todas AS Unidades SSR UP6-40-HA
Dados Eléctricos Todas AS Unidades SSR 30E-HA
Dados Eléctricos
Não aponte o fluxo de ar à face ou aos olhos
Instruções DE Funcionamento Geral
Funcionamento Geral
Instruções DE Funcionamento Electropneumática
Teste DE Função
Carregue no botão Reset Rearmar 8. O indicador de avaria
Paragem NORMAL/EMERGÊNCIA
Http//air.ingersollrand.com
Esquema Eléctrico DE Voltagem Total
Interruptor, rearmar
Pressóstato
Interruptor, pressão de refrigerante alta opção
Cliente
Esquema Eléctrico Estrela Triângulo
Electroválvula opção modelação
Interruptor, pressão ventoinha opção
Contactor, estrela
Relé, arranque estrela 10 segundos
Diagrama DA Tubagem DE Controlo
Rearranque POR Falta DE Energia opcional
Instruções DE Funcionamento Opção Intellisys
Controlo Intellisys E Instrumentos Antes do Arranque
Tempo DE Rearranque POR Falta DE Energia
E.D. Horas EM Carga
10 L.E.D. Sinalizador DE Alarme
E.D. Horas Totais
E.D. Sinalizador DE CARGA/VAZIO
Modos DE Controlo DA Máquina Controlo DE Capacidade
Sinalizador DE Tensão
Sinalizador DE Rearranque Automático
Controlo Carga Vazio
Perda DA Tensão DE Comando
Sensor DE Pressão
Falha DE Calibração
Falha no Arranque Remoto
Controlo ACS Intellisys c/ Opção DE Modulação Apenas
Controlo DE Modulação
Código
Controlo de Modulação
Análise de Avarias
Operação Opção DE Rearranque Após Falha DE Corrente
Teste de funcionamento
Sensor, temperatura ar secador opção
Sensor, pressão, linha/reservatório
Sensor, temperatura, descarga airend
1FU, 2FU Fusíveis, voltagem principal
Interruptor, arranque remotoopção
Contactos, alarme remoto, opção
Buzina, interrupção de corrente opção
Interruptor, paragem remotaopção
Módulo, opção
1Sa, b Contacto, contactor estrela auxiliar
Electroválvula linha / reservatório
Conservação DE Rotina
Manutenção
Período Manutenção
Procedimento Para Mudança do Filtro DE Refrigerante
Procedimento Para Atestar O Refrigerante
Procedimento Para a Mudança DE Refrigerante
Procedimento Para Substituição do Elemento do Filtro DE AR
Procedimento para verificação do nível de óleo
Procedimento Para Substituição DOS Cartuchos do Separador
Manutenção do Secador Opção Secador Advertência
Atestamento com óleo
Para Afinar O Ponto DE Regulação Inferior
Para Verificar O Ponto DE Regulação Inferior
Para Afinar O Ponto DE Regulação Superior
Procedimento Para Substituição DE Correia / Tensor DE GÁS
Manutenção do Separador DE Humidade
Operação
Solução DE Problemas Causa Acção
Electroválvula DE Drenagem Descrição do Produto
Regulações do Temporizador
Ajuste DA Válvula DE Controlo DA Modulação
Figura 2 Válvula DE Modulação
Diagn Óstico DE Avarias
Avaria Causa Solução
Diagnóstico DE Avarias
Opção Secador