Ingersoll-Rand EP50-PE, SSR UP6 40, SSR UP6 50PE, HXP50-PE, HP50-PE Installation / Handling, 128.3A

Models: HXP50-PE

1 208
Download 208 pages 23.94 Kb
Page 21
Image 21

 

 

 

 

 

 

 

INSTALLATION / HANDLING

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA – ALL UNITS SSR UP6–40–HA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard voltage

200V

230V

 

 

380V

 

460V

 

575V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PACKAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor enclosure

ODP

 

TEFC

ODP

 

TEFC

 

ODP

 

TEFC

ODP

 

TEFC

ODP

 

TEFC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power (nominal)

 

 

 

 

 

 

 

 

40HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full load current at maximum

136.0A

 

128.3A

119.0A

 

111.5A

 

71.6A

 

65.1A

59.5A

 

56.9A

47.6A

 

44.7A

 

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full load current at maximum

 

123.5A

 

116.0A

 

 

61.7A

 

58.1A

 

 

pressure with dryer option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting current FV (STAR)

706 (265)

617 (231)

 

374 (140)

309 (115)

247 (93)

 

 

 

 

 

 

 

 

 

 

 

 

Starting current FV (STAR)

 

652 (268)

 

 

323 (131)

 

 

with dryer option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting time FV (STAR)

 

 

 

 

 

 

 

3–5 Sec (7–10 Sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starts per hour (maximum)

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA – FV / Star Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control voltage

 

 

 

 

 

 

 

120VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum fuse rating

175A

150A

 

 

90A

 

75A

 

60A

 

See note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum fuse rating with dryer

 

175A

 

150A

 

 

80A

 

75A

 

 

option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum wire size AWG

 

4/0

 

3/0

 

 

2

 

3

 

4

 

See note 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA – ALL UNITS SSR 30E–HA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard voltage

200V

230V

 

 

380V

 

460V

 

575V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PACKAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor enclosure

ODP

 

TEFC

ODP

 

TEFC

 

ODP

 

TEFC

ODP

 

TEFC

ODP

 

TEFC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power (nominal)

 

 

 

 

 

 

 

 

30HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full load current at maximum

109.2A

 

100.9A

95.0A

 

87.8A

 

57.5A

 

53.1A

47.5A

 

43.9A

38.0A

 

38.3A

 

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full load current at maximum

 

99.5A

 

92.3A

 

 

49.7A

 

46.1A

 

 

pressure with dryer option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting current FV (STAR)

567 (212.4)

493.2 (184.8)

 

298.5 (111.8)

246.6 (92.4)

197.3 (73.9)

 

 

 

 

 

 

 

 

 

 

 

 

Starting current FV (STAR)

 

516.6 (193.5)

 

 

258 (96.7)

 

 

with dryer option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting time FV (STAR)

 

 

 

 

 

 

 

3–5 Sec (7–10 Sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starts per hour (maximum)

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA – FV / Star Delta

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control voltage

 

 

 

 

 

 

 

120VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum fuse rating

150A

 

125A

125A

 

125A

 

75A

 

75A

60A

 

60A

50A

 

50A

 

See note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum fuse rating with dryer

 

150A

 

150A

 

 

75A

 

75A

 

 

option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum wire size AWG

 

3/0

 

1/0

 

 

3

 

4

 

6

 

See note 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

http://air.ingersollrand.com

SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE,

HP50–PE, HXP50–PE

Page 21
Image 21
Ingersoll-Rand EP50-PE, SSR UP6 40, SSR UP6 50PEI HF50-PE, HXP50-PE, HP50-PE manual Installation / Handling, 128.3A