4: System Control
L1 Controller Functions
The following list summarizes the control and monitoring functions that the L1 controller
performs:
Controls voltage margining within the IRUs
Controls and monitors IRU fan speeds
Reads system identification (ID) PROMs
Monitors voltage levels and reports failures
Monitors and controls warning LEDs on the IRU
Monitors the On/Off power switch
Monitors the reset switch and the nonmaskable interrupt (NMI) switch
Reports the population of the PCI cards and the power levels of the PCI slots in installed I/O
blades
Powers on the PCI slots and their associated LEDs
L1 Front Panel Display