7: Troubleshooting and Diagnostics

Compute/Memory Blade LEDs

Each compute/memory blade installed in an IRU has a total of eight LED indicators arranged in two rows of four and

behind the perforated of the blade:

One green LED shows power-on complete status for the blade.

One red LED shows power failure or bad voltage status within the blade.

Two green NUMAlink indicators show NI0 and NI1 connection status between the blade and the router board within the IRU. Constant green is a good connection.

Four amber (heartbeat LEDs) indicate compute activity (the LEDs light up according to the number, activity and type of processors installed in the blade). If the IRU is fully powered on and booted and none of the amber LEDs are lit there is most likely a problem with the compute/memory blade. Try reseating the blade in the slot. Confirm the two green NUMAlink status LEDs are on. If there is no LED activity on the blade, it must be replaced.

148

007-4857-002

Page 170
Image 170
Intel SGI Altix 450 manual Compute/Memory Blade LEDs