1: System Installation
Installing the IRUs in a Rack
This section describes how to install the IRUs that compose an Altix 450 system in a rack. This section also describes how to remove the IRUs from a rack. You can use the instructions to rackmount one or more IRUs in a 20U (short) or 42U (tall) Altix rack.
Caution: Always use at least two people when moving, installing, or removing a rackmounted ! Altix 450 IRU.
This rackmounting information is found in the following sections:
• “Determining Space Requirements” on page 24
• “Determining Where to Attach Rails in a Rack” on page 25
• “Rackmounting IRUs with Shelf Rails” on page 26
Determining Space Requirements
Table
Table | IRU Space Requirements |
|
|
|
|
Height |
| (5U) 8.68 inches (22 cm) |
Width |
| 17.5 inches (44.45 cm) |
Depth |
| 32.5 inches (82.5 cm) with blower attached |
Weight |
| ~130 lb (59 kg) max configa |
Required front clearance for IRU | 8.25 in. (20.96 cm) | |
Required rear clearance for IRU | 10 in. (25.40 cm) | |
Required side clearance for IRU | No clearance requirement | |
Required front clearance for rack | 48 in. (122 cm) | |
Required rear clearance for rack | 48 in. (122 cm) |
a.Weight will vary slightly depending on the number of blades installed and the amount of DIMMs installed, and on whether you have one or two disk drives in the IRU.
24 |
|