Figure 22. X-6 Power input connection.

3.3.4X8 LS RS485 Out Connector

The RS485 output from the Light Sensor to the RS485-to-Ethernet converter connector is X8. The connections from X8 to the converter are shown in Table 6 and Figure 23

Table 6

X8 to converter connector

 

 

 

 

 

 

X8 Pin #

Signal

Description

Connection to RS485-to-Ethernet converter

 

 

 

 

 

 

1

+24V dc

24V Power output

V+ power input

 

 

 

 

 

 

2

Gnd

Power return

V- power input

 

 

 

 

 

 

3

+12V dc

12V Power output

 

 

 

 

 

 

 

4

Gnd

Power return

 

 

 

 

 

 

 

5

D0+

RS485 databus D0+

D+ Port 2

 

 

 

 

 

 

6

D0-

RS485 databus D0-

D- Port 2

 

 

 

 

 

 

7

D1+

RS485 databus D1+

D+ Port 1

 

 

 

 

 

 

8

D1-

RS485 databus D1-

D- Port1

 

 

 

 

 

 

 

 