VIS-CAM System
84 Appendix C: Two Cameras, One-Flash Configuration

Table 35 Master to slave connections.

Master Flash Connector (X5)
Slave Laser Connector (X7)
Pin 2
Pin 2
Pin 3
Pin 3
Pin 5
Pin 1
Junction Panel trigger polarity switch in position “positive going edge”
Master camera flash must be set to “auto” in Properties section of ENSetup software
Slave camera flash must be set to “light sensor control” in properties section of ENSetup
software