VIS-CAM System

Table 35 Master to slave connections.

Master Flash Connector (X5)

Slave Laser Connector (X7)

 

 

Pin 2

Pin 2

 

 

Pin 3

Pin 3

 

 

Pin 5

Pin 1

Junction Panel trigger polarity switch in position “positive going edge”

Master camera flash must be set to “auto” in Properties section of ENSetup software

Slave camera flash must be set to “light sensor control” in properties section of ENSetup software

 

 

 

84

Appendix C: Two Cameras, One-Flash Configuration

Page 96
Image 96
JAI TS-9720EN, TS-1327EN, TS-2030EN manual Master to slave connections, Master Flash Connector Slave Laser Connector