JAI TS-9720EN, TS-1327EN 5 X14 Trigger Input Connector, Trigger input connector, Trigger polarity

Models: TS-9720EN TS-2030EN TS-1327EN

1 112
Download 112 pages 45.73 Kb
Page 39
Image 39

VIS-CAM System

Figure 23. Wiring for the X8 to converter connector.

Up to four cameras can be connected to one Light Sensor using one Moxa Nport 5232 Device Server. If more than four cameras need to be connected to the same Light Sensor please refer to “Appendix E: Moxa N-Port 5232 Configuration” on page 93 in this Manual.

3.3.5X14 Trigger Input Connector

The Trigger input connection to the J-Panel is connector X14. The connections are listed in Table 7

Table 7

Trigger input connector.

 

 

 

 

 

X14 Pin #

Signal

Description

Connection to

 

 

 

 

1

Trig0+

Positive Trigger input to camera 0

Trigger device positive terminal

 

 

 

 

2

Trig0-

Negative Trigger input to camera 0

Trigger device negative terminal

 

 

 

 

3

Trig1+

Positive Trigger input to camera 1

Trigger device positive terminal

 

 

 

 

4

Trig1-

Negative Trigger input to camera 1

Trigger device negative terminal

 

 

 

 

3.3.5 (a) Trigger polarity

The switches S3 and S5 sets the trigger polarity:

If the trigger signal is normally low (no voltage at trigger input) the switch shall be in position

Arrow up - positive going

If the trigger signal is normally high (voltage at trigger input) the switch shall be in position

Installing the Vehicle Imaging Subsystem