Lantronix XN manual To Configure Tunnel Serial Settings, Tunnel Packing Mode Settings

Models: XN

1 104
Download 104 pages 14.08 Kb
Page 49
Image 49

 

 

7: Line and Tunnel Settings

 

 

 

 

Tunnel Serial

Description

 

Settings (continued)

 

 

Protocol

Protocol information here is display only. Go to the section, To Configure

 

 

Line Settings to modify these settings.

 

 

 

 

DTR

Select the conditions in which the Data Terminal Ready (DTR) control signal

 

 

on the serial line are asserted. Choices are:

 

 

Unasserted

 

 

TruPort = the DTR is asserted whenever either a connect or an accept

 

 

mode tunnel connection is active with the Telnet Protocol RFC2217 saying

 

 

that the remote DSR is asserted.

 

 

Asserted while connected = the DTR is asserted whenever either a

 

 

connect or an accept mode tunnel connection is active.

 

 

Continuously asserted

 

 

 

To Configure Tunnel Serial Settings

Using Web Manager

To configure the Serial Settings for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Serial Settings.

Using the CLI

To enter Tunnel 1 command level: enable -> tunnel 1 -> serial

Using XML

Include in your file: <configgroup name=”tunnel serial” instance=”1”>

Packing Mode

With Packing, data from the serial Line is not sent over the network immediately. Instead, data is queued and sent in segments, when either the timeout or byte threshold is reached. Packing applies to both Accept and Connect Modes.

 

Table 7-4 Tunnel Packing Mode Settings

 

 

 

Tunnel Packing Mode

 

Description

Settings

 

 

Mode

 

Configure the Tunnel Packing Mode. Choices are:

 

 

Disable = Data not packed.

 

 

Timeout = data sent after timeout occurs.

 

 

Send Character = data sent when the Send Character is read on the Serial

 

 

Line.

 

 

 

Threshold

 

Set the threshold (byte count). If the received serial data reaches this

 

 

threshold, then the data will be sent on the network. Valid range is 100 to

 

 

1450 bytes. Default is 512.

 

 

 

Timeout

 

Set the timeout value, in milliseconds, after the first character is received on

 

 

the serial line, before data is sent on the network. Valid range is 1 to 30000

 

 

milliseconds. Default is 1000.

 

 

 