7: Line and Tunnel Settings

 

 

Table 7-5 Tunnel Accept Mode Settings

 

 

 

 

 

Tunnel Accept Mode

 

Description

 

Settings

 

 

 

Mode

 

Set the method used to start a tunnel in Accept mode. Choices are:

 

 

 

Disable = do not accept an incoming connection.

 

 

 

Always = accept an incoming connection (default).

 

 

 

Any Character = start waiting for an incoming connection when any

 

 

 

character is read on the serial line.

 

 

 

Start Character = start waiting for an incoming connection when the

 

 

 

start character for the selected tunnel is read on the serial line.

 

 

 

Modem Control Asserted = start waiting for an incoming connection as

 

 

 

long as the Modem Control pin (DSR) is asserted on the serial line until

 

 

 

a connection is made.

 

 

 

Modem Emulation = start waiting for an incoming connection when

 

 

 

triggered by modem emulation AT commands. Connect mode must

 

 

 

also be set to Modem Emulation.

 

 

 

 

 

Local Port

 

Set the port number for use as the network local port. The default local port

 

 

 

number for each supported serial line number progresses sequentially in

 

 

 

equal value so that Tunnel X : 1000X. For example:

 

 

 

Tunnel 1 : 10001

 

 

 

Tunnel 2 : 10002

 

 

 

 

 

Protocol

 

Select the protocol type for use with Accept Mode:

 

 

 

SSH

 

 

 

SSL

 

 

 

TCP (default protocol)

 

 

 

TCP AES

 

 

 

Telnet

 

 

 

 

 

Credentials

 

Specifies the name of the set of RSA and/or DSA certificates and keys to

 

 

 

be used for the SSL connection.

 

 

 

 

 

AES Encrypt Key

 

Specify the text or hexadecimal advanced encryption standard (AES) key

 

 

 

for encrypting outgoing data.

 

 

 

 

 

AES Decrypt Key

 

Specify the text or hexadecimal AES key for decrypting incoming data.

 

 

 

 

 

TCP Keep Alive

 

Enter the time, in milliseconds, the PremierWave waits during a silent

 

 

 

connection before checking if the currently connected network device is

 

 

 

still on the network. If the unit gets no response after 1 attempt, it drops

 

 

 

the connection. Enter 0 to disable.

 

 

 

 

 

Flush Serial

 

Set whether the serial line data buffer is flushed upon a new network

 

 

 

connection. Choices are:

 

 

 

Enabled = serial data buffer is flushed on network connection

 

 

 

Disabled = serial data buffer is not flushed on network connection

 

 

 

(default)

 

 

 

 

 

Block Serial

 

Set whether Block Serial is enabled for debugging purposes. Choices are:

 

 

 

Enabled = if Enabled, incoming characters from the serial line will not

 

 

 

be forwarded to the network. Instead, they will be buffered and will

 

 

 

eventually flow off the serial line if hardware or software flow control is

 

 

 

configured.

 

 

 

Disabled = this is the default setting; incoming characters from the

 

 

 

Serial Line are sent on into the network. Any buffered characters are

 

 

 

sent first.

 

 

 

 

PremierWave XN User Guide

51

Page 51
Image 51
Lantronix XN manual Tunnel Accept Mode Settings, Tunnel Accept Mode Description Settings