Lantronix XN manual To Configure Tunnel Accept Mode Settings, Connect Mode, Block Network

Models: XN

1 104
Download 104 pages 14.08 Kb
Page 52
Image 52

 

 

7: Line and Tunnel Settings

 

 

 

 

Tunnel Accept Mode

Description

 

Settings (continued)

 

 

Block Network

Set whether Block Network is enabled for debugging purposes. Choices

 

 

are:

 

 

Enabled = if Enabled, incoming characters from the network will not be

 

 

forwarded to the Serial Line. Instead, they will be buffered and will

 

 

eventually flow off the network side.

 

 

Disabled = this is the default setting; incoming characters from the

 

 

network are sent on into the Serial Line. Any buffered characters are

 

 

sent first.

 

 

 

 

Password

Enter a password. This password can be up to 31 characters in length and

 

 

must contain only alphanumeric characters and punctuation. When set,

 

 

clients must send the correct password string to the unit within 30 seconds

 

 

from opening network connection in order to enable data transmission.

 

 

The password sent to the unit must be terminated with one of the following:

 

 

0A (Line Feed)

 

 

00 (Null)

 

 

0D 0A (Carriage Return/Line Feed)

 

 

0D 00 (Carriage Return/Null)

 

 

If, Prompt for Password is set to Enabled and a password is provided, the

 

 

user will be prompted for the password upon connection.

 

 

 

 

Email on Connect

Select an email profile number to which an email notification will be sent

 

 

upon the establishment of an accept mode tunnel.

 

 

 

 

Email on Disconnect

Select an email profile number to which an email notification will be sent

 

 

upon the disconnection of an accept mode tunnel.

 

 

 

To Configure Tunnel Accept Mode Settings

Using Web Manager

To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Accept Mode.

Using the CLI

To enter Tunnel 1 Accept Mode command level: enable -> tunnel 1 -> accept

Using XML

Include in your file: <configgroup name="tunnel accept" instance="1">

Connect Mode

In Connect Mode, the PremierWave XCPremierWave XNPremierWave ENEDS-MD4/8/16 continues to attempt an outgoing connection on the network, until established. If the connection attempt fails or the connection drops, then it retries after a timeout. The remote node on the network must listen for the Connect Mode’s connection.

For Connect Mode to function, it must be enabled, have a remote station (node) configured, and a remote port configured (TCP or UDP). When established, Connect Mode is always on. Enter the remote station as an IP address or DNS name. The PremierWave XCPremierWave XNPremierWave ENEDS-MD4/8/16 will not make a connection unless it can resolve the address.

PremierWave XN User Guide

52

Page 52
Image 52
Lantronix XN To Configure Tunnel Accept Mode Settings, Connect Mode, Block Network, Email on Connect, Email on Disconnect