7: Line and Tunnel Settings

 

 

 

 

 

Line Settings (continued)

Description

 

Xon Char

 

Set Xon Char to be used when Flow Control is set to Software. Prefix decimal

 

 

 

with \ or prefix hexadecimal with 0x or prefix a single control character

 

 

 

<control>.

 

 

 

 

 

Xoff Char

 

Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal

 

 

 

with \ or prefix hexadecimal with 0x or prefix a single control character

 

 

 

<control>.

 

 

 

 

 

Gap Timer

 

Set the Gap Timer delay to Set the number of milliseconds to pass from the

 

 

 

last character received before the driver forwards the received serial bytes.

 

 

 

By default, the delay is four character periods at the current baud rate

 

 

 

(minimum 1 msec).

 

 

 

 

 

Threshold

 

Set the number of threshold bytes which need to be received in order for the

 

 

 

driver to forward received characters.

 

 

 

 

 

 

Table 7-2 Line Command Mode Settings

 

 

 

 

 

Line Command

Description

 

Mode Settings

 

 

 

Mode

Set the Command Mode state of the Line. When in Command Mode, a CLI session

 

 

operates exclusively on the Line. Choices are:

 

 

Always

 

 

User Serial String

 

 

Disabled

 

 

Note: In order to enable Command Mode on the Line, Tunneling on the Line must

 

 

be Disabled (both Connect and Accept modes). Also, custom baud rates are not

 

 

supported in Command Mode.

 

 

 

 

Wait Time

Enter the amount of time to wait during boot time for the Serial String. This timer

 

 

starts right after the Signon Message has been set on the Serial Line and applies

 

 

only if mode is “Use Serial String”.

 

 

 

 

Serial String

Enter the Text or Binary string of bytes that must be read on the Serial Line during

 

 

boot time in order to enable Command Mode. It may contain a time element to

 

 

specify a required delay in milliseconds x, formed as {x}. Applies only if mode is

 

 

“User Serial String”. It may contain a binary character(s) of the form [x]. For

 

 

example, use decimal [12] or hex [0xc].

 

 

 

 

Echo Serial String

Select Enable or Disable for Echo Serial String. Applies only if mode is “User Serial

 

 

String”. Select enable to echo received characters backed out on the line while

 

 

looking for the serial string.

 

 

 

 

Signon Message

Enter the string of bytes to be sent to the Serial Line during boot time. It may contain

 

 

a binary character(s) of the form [x]. For example, use decimal [12] or hex [0xc].

 

 

 

 

To Configure Line Settings

Note: The following section describes the steps to view and configure Line 1 settings; these steps apply to other line instances of the device.

Using Web Manager

To configure a specific line, click Line in the menu and select Line 1 -> Configuration (Table 7-1).