8.5Verifying the Coax Interface with the SIMM for IPDS

To verify the Adapter for SCS configuration, print a SCS IDB dump page. Follow these steps:

1.Press Menu> until NETWORK MENU displays. Press Select.

2.Press Menu> until NETWORK OPTION 1 displays. Press Select. (This example assumes the Adapter for SCS is installed in option connector 1.)

3.Press Menu> until SCS MENU 1 displays. Press Select.

4.Press Menu> until you see TEST OPTIONS. Press Select.

5.Press Menu> until you see SCS IDB DUMP. Press Select.

6.Press Menu> until you see Print. Press Select.

The printer returns to Ready when the IDB Dump has been printed.

The SCS IDB dump contains all the current adapter settings including the IPDS Enabled setting and the current Adapter for SCS firmware level. Look for the sentence near the top of the page telling you whether IPDS is active or not active.

Additional Information

Please refer to the Adapter for SCS, Coax/Twinax Connection, Installation and User's Guide for a detailed description on how to set up the Adapter for SCS.