Lincoln Electric SVM104-A service manual J21

Models: SVM104-A

1 114
Download 114 pages 54.03 Kb
Page 64
Image 64

TOC

TOC

F-23

TROUBLESHOOTING & REPAIR

TRANSISTOR MODULE TEST

Return to Section

to Section TOC

Return to Master

to Master TOC

10.Replace the terminal screw snugly, a little more than finger tight. The Transistor Module is mounted behind the Power Board and the terminal screw completes the electrical connection.

11.Perform the following resi- tance tests listed in Table F.1:

NOTE: Meter lead polarity must be observed for these resistance tests.

a. If a low resistance is measured in both polarities, the transistor module is “shorted.” Replace the transis- tor module, the Power Board, and the Control Board.

b. If a high resistance is measured in both polarities, the transistor module is “open.” Replace the transistor module, the Power Board, and the Control Board.

12.Replace all leads.

a.Torque screws to 17 in./lbs. ( 1.9 N.M.)

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

H1

LEAD

H2

LEAD

C

LEADS

NEG

LEAD

#40

LEADS

MOUNTING1J21 SCREWS

 

 

 

J21

H1

 

40 G1

 

 

B

G2

 

 

 

H2

4J20

 

 

 

 

 

 

2J20

J20

1J20

 

 

C

NEG

#40

3J22 J22 1J22

4J222J22

POWER BOARD

L7941

FIGURE F.9-Transistor Module Test Points

PRO-CUT 60

Page 64
Image 64
Lincoln Electric SVM104-A service manual J21