TROUBLESHOOTING & REPAIR

F-16

TORCH, TORCH CABLE ASSEMBLY, INTERNAL TRIGGER,

AND SAFETY CIRCUIT TEST

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

TORCH AND CABLE

RESISTANCE TEST

PROCEDURE

1.Turn PRO-CUT 60 ON/OFF Power Switch to OFF.

2.Disconnect main power supply to machine.

3.Perform the CAPACITOR DISCHARGE PROCEDURE.

4.Disconnect and remove the torch cable from the bulkhead com- partment. See Figure F.3.

a.Locate the torch cable access door on the Right Case Side Assembly of the machine.

b.Remove the one sheet metal screw on the left-hand side of the access door and swing open the door.

c.Test for a voltage across the stud marked WORK and the bulkhead connector (brass fitting). NO voltage should be present. If a voltage is present, STOP. DO NOT perform this test. Contact the Lincoln Electric Service Department. If no voltage is present, continue test procedure.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Right Case Side Assembly

Torch

Cable

Access

Door

 

 

PILOT

 

 

WORK

 

Strain Relief Clamp

Pilot Lead

4-Pin Connector

Bolt Hole

Bulkhead Connector

Work Stud

(Brass Fitting)

Work Lead

Gas Line

Cable Boot

FIGURE F.3 - Torch Cable Connections